Association of vestibule depth with peri-implant inflammation and soft tissue stability independent of keratinized mucosa width: a cross-sectional study.
Berkin Inan, Hanife Merva Parlak, Gokcen Akcicek, M Baris Guncu, Abdullah C Akman, Ayhan Parmaksiz, H Gencay Keceli, Guliz N Guncu
Department of Periodontology, Hacettepe University Faculty of Dentistry, Ankara, Turkey. · Department of Dentomaxillofacial Radiology, Hacettepe University Faculty of Dentistry, Ankara, Turkey.
Key points
From the paper's conclusion- VD was not significantly associated with peri-implant inflammation or soft tissue stability, whereas KMW showed a stronger association with these parameters. These findings suggest that KMW, independent of VD, plays an important role in peri-implant soft tissue health in the posterior mandible.
Abstract
PURPOSE: This study evaluated whether vestibule depth (VD) affects peri-implant inflammation and mucosal margin stability in the posterior mandible independently of keratinized mucosa width (KMW). METHODS: A total of 129 patients, each with a single implant in the mandibular premolar or molar region, were included. Clinical variables, including gingival index, plaque index (PI), peri-implant probing depth, clinical attachment level (CAL), gingival bleeding time index (GBTI), VD, KMW, mucosal thickness (MT), mucosal recession (MR), peri-implant soft tissue phenotype, and peri-implant soft tissue dehiscence (PISTD), were assessed. Multiple linear regression analysis was performed to determine the associations of GBTI, MR, and PISTD type with the independent variables PI, KMW, age, implant diameter, sex, function time, implant location, CAL, MT, VD, and phenotype classification. RESULTS: Implants with adequate KMW (≥2 mm) displayed greater VD and MT, less MR, and a thicker phenotype than implants with inadequate KMW (<2 mm) (P<0.001 for all). PISTD class II defects were observed more frequently in the group with adequate KMW, whereas class III defects were more common among the patients with inadequate KMW (P=0.001). Implants with sufficient VD (≥6 mm) showed greater KMW and MT and less MR than implants with insufficient VD (<6 mm) (P=0.026 for MR; P<0.001 for all other comparisons). Based on the multiple regression analysis, KMW was significantly associated with GBTI, MR, and PISTD types and subtypes (P<0.05 for all), whereas VD was not significantly associated with any of these variables. CONCLUSIONS: VD was not significantly associated with peri-implant inflammation or soft tissue stability, whereas KMW showed a stronger association with these parameters. These findings suggest that KMW, independent of VD, plays an important role in peri-implant soft tissue health in the posterior mandible.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Keratinized Mucosa Width and Mucosal Thickness on Implant Outcomes and Brushing Discomfort: A 25-Year Cohort Study.Journal of clinical periodontology · 2026
- Relationship between peri-implant soft tissue characteristics and peri-implant health and mucositis: a cross-sectional study.The Saudi dental journal · 2026
- Retrospective study on the outcomes of vestibuloplasty with a xenogeneic collagen matrix.Journal of periodontal & implant science · 2026
- Keratinised mucosa width and peri-implant disease during supportive peri-implant care: A follow-up analysis using cluster-adjusted sensitivity models in an established maintenance cohort.International journal of oral implantology (Berlin, Germany) · 2026
- Soft tissue grafting for the prevention and management of peri-implantitis.Periodontology 2000 · 2026
- The Role of the Keratinized Mucosa in Peri‐Implant Diseases Onset and Brushing Discomfort: A 10‐Year Follow‐UpClinical Oral Implants Research · 2026