An Observational Study on Diagnostic Accuracy of Lung Ultrasound Compared to High-resolution Computed Tomography Scan of Thorax in Patients Admitted with Respiratory Problems to Critical Care Unit of a Tertiary Care Hospital in Eastern India
Antara Dhenki, Sugata Dasgupta, Arpita Choudhury, Tanmoy Mondal, Soma Mukhopadhyay, Jayati Bardhan
R. G. Kar Medical College and Hospital · Institute of Post Graduate Medical Education and Research
Key points
From the paper's conclusion- An Observational Study on Diagnostic Accuracy of Lung Ultrasound Compared to High-resolution Computed Tomography Scan of Thorax in Patients Admitted with Respiratory Problems to Critical Care Unit of a Tertiary Care Hospital in Eastern India.
Abstract
Background and aim: Acute respiratory failure in critically ill patients poses a diagnostic challenge, often requiring high-resolution computed tomography (HRCT) of the thorax for definitive diagnosis. However, the inherent risks of transporting hemodynamically unstable patients to the radiology suite necessitate safer bedside alternatives. The objective of the present study was to evaluate the diagnostic yield of both six-zone and extended 12-zone lung ultrasound (LUS) compared to HRCT thorax. Patients and methods: In this cross-sectional observational study conducted on 150 patients, admitted in the critical care unit and surgical intensive care unit (ICU), six-zone and 12-zone LUS were performed within 24 hours of an HRCT thorax for the most common etiologies of respiratory failure. Diagnostic yield of six-zone and 12-zone LUS to HRCT thorax was compared through calculating Cohen's kappa statistic (value ≥ 0.7) being interpreted as indicating strong agreement between two modalities. Results: For consolidation, the 12-zone protocol showed superior sensitivity (0.84 vs 0.76) and negative predictive value (NPV) (0.61 vs 0.47) compared to the six-zone protocol. Agreement with HRCT was "moderate" for the six-zone protocol (kappa = 0.52) but "substantial" for the 12-zone protocol (kappa = 0.81). For pleural effusion and edema, LUS maintained high sensitivity (>0.85). Conclusion: Both LUS protocols are effective, but the 12-zone protocol significantly improves the diagnostic yield for lung consolidation, providing substantial agreement with HRCT. How to cite this article: Dhenki A, Dasgupta S, Choudhury A, Mondal T, Mukhopadhyay S, Bardhan J. An Observational Study on Diagnostic Accuracy of Lung Ultrasound Compared to High-resolution Computed Tomography Scan of Thorax in Patients Admitted with Respiratory Problems to Critical Care Unit of a Tertiary Care Hospital in Eastern India. Indian J Crit Care Med 2026;30(3):237-243.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Analysis of Lung Ultrasound, Computed Tomography, and X-ray in the Diagnosis of Common Pathologies among Critically Ill Mechanically Ventilated Patients—A Prospective Observational StudyIndian Journal of Critical Care Medicine · 2025
- An Integrated Prehospital Point‐of‐Care Lung Ultrasound Protocol for Patients With DyspneaJournal of Ultrasound in Medicine · 2026
- Accuracy of lung ultrasound in the diagnosis of acute respiratory distress syndrome: a systematic review and meta-analysis.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Lung ultrasound.Current opinion in critical care · 2026
- Streamlined point-of-care ultrasound examination for pulmonary tuberculosis.medRxiv : the preprint server for health sciences · 2026
- Diagnostic accuracy of nurse‑performed lung ultrasound for pulmonary congestion in acute kidney injury: An exploratory study.International journal of nursing knowledge · 2026