A molecularly imprinted electrochemical sensor integrated with conversion factor T strategy for rapid and selective determination of lutein esters in marigold extracts.
Ziyu Zhu, Benshu Chen, Aiqin Luo, Yong Cong, Wei Li, Liquan Sun, Axin Liang
Key Laboratory of Molecular Medicine and Biotherapy, the Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing 100081, China. · Lacare Nutritional Technology (Beijing) Co., Ltd, Beijing 100192, China.
Key points
From the paper's conclusion- The proposed strategy integrates rapid electrochemical sensing with conversion factor analysis, enabling indirect quantification of multiple lutein esters from a single target analyte.
Abstract
Establishing a comprehensive analytical method capable of accurately reflecting the composition of major lutein esters and enabling their rapid quantification is essential for the quality evaluation of marigold products. In this study, the major lutein esters present in marigolds were first identified by HPLC-MS, and a novel 'conversion factor T' strategy was established. Using lutein dipalmitate as the reference marker, the contents of other major lutein esters were calculated based on their relative conversion factors. To further simplify the analytical procedure, a molecularly imprinted electrochemical sensor based on conductive Ni3(HITP)2-MOF was developed for the rapid determination of lutein dipalmitate. The introduction of Ni3(HITP)2-MOF enhanced the electrode conductivity by approximately fourfold compared with the bare electrode. The sensor exhibited a wide linear range of 0.01-100 μM and a low detection limit of 8.20 nM toward lutein dipalmitate. Four major lutein esters, namely lutein dimyristate, lutein myristate-palmitate, lutein dipalmitate, and lutein palmitate-stearate, were quantified, and the corresponding conversion factors (T d , T m , and T p ) were determined as 0.903, 0.964, and 1.035, respectively. The proposed strategy integrates rapid electrochemical sensing with conversion factor analysis, enabling indirect quantification of multiple lutein esters from a single target analyte. Furthermore, the method was successfully applied to the quality evaluation of marigold extracts and commercial eye care products, demonstrating its potential for rapid routine analysis and quality control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Green Extraction of Lutein Esters From Marigold Using a Propyl Acetate/Ethanol/Water Surfactant‐Free Microemulsion: Structure‐Performance Relationship and Process OptimizationJournal of Food Process Engineering · 2026
- Development, Optimization, and Validation of an HPTLC Method for Quantification of Lutein in Fermented and Enzyme‐Treated Tagetes erecta LinnChemistrySelect · 2026
- Rational Design of a Molecularly Imprinted Sensor on a Biomass Carbon Platform for Glyphosate Monitoring in Traditional Chinese MedicinesPolymers · 2025
- Ratiometric detection of liquiritin in Glycyrrhiza uralensis using an rGO/Ti3C2Tx-based electrochemical sensor.Talanta · 2026
- Highly sensitive electrochemical sensor for the detection of rutin based on graphite-doped plate-like FER zeolite.Food chemistry · 2026
- A Highly Efficient Ternary Composite Sensor with a Thiacalix[4]arene-Based Metal−Organic Framework, Spherical Graphite, and Multi-Walled Carbon Nanotubes for Enhanced Electrochemical Sensing of RutinCrystal Growth & Design · 2026