Accuracy of Rapid Tests for the Diagnosis of Acute Dengue in Southern Nigeria.
Iriagbonse I Osaigbovo, Isaac O Igbarumah, Alex Bazuaye, Chizoba Igbokwe, Benson U Okwara, Emmanuel Osaigbovo, Mohammed Yahaya, Abayomi A Olufemi,
Department of Medical Microbiology, College of Medical Sciences, University of Benin, Benin City, Nigeria. · Molecular Diagnostic and Virology Laboratory, University of Benin Teaching Hospital, Benin City, Nigeria.
Key points
From the paper's conclusion- Although both IgG and IgM components of the antibody RDT evaluated demonstrated poor diagnostic metrics for acute dengue detection, the NS1 antigen RDT had excellent diagnostic parameters, showing promise as a faster alternative for primary diagnosis and routine surveillance of dengue in Southern Nigeria.
Abstract
Dengue is an emerging public health concern in West Africa. Although rapid diagnostic tests (RDTs) have facilitated dengue diagnosis, surveillance, and outbreak detection in other endemic regions, there is a paucity of data on their accuracy in African populations. Our objective was to evaluate the diagnostic accuracy of commercial dengue RDTs in southern Nigeria. A retrospective cross-sectional study was conducted in Benin City, Nigeria, using archived plasma samples previously tested with reverse transcriptase-polymerase chain reaction (RT-PCR) as the reference method. Laboratory personnel blinded to the reference test results evaluated a dengue nonstructural (NS) 1 antigen RDT and a combined IgM/IgG antibody test (assessing the individual antibody components separately). Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) were estimated for NS1 antigen, IgM, and IgG and reported with 95% confidence intervals (CIs). Of 145 samples selected for the evaluation, 95 (65.5%) were dengue RT-PCR-positive. The sensitivity, specificity, PPV, and NPV of the NS1 antigen RDT with 95% CI were 94.7% (91.5%-98.5%), 100% (98.7%-100.0%), 100% (97.9%-100.0%), and 90.9% (83.5%-98.5%), respectively; its overall accuracy was 96.6% in comparison with 53.8% for IgG and 31.7% for IgM. The area under the receiver operating characteristic curve was 0.974 for NS1 antigen, 0.5 for IgG, and 0.427 for IgM. Although both IgG and IgM components of the antibody RDT evaluated demonstrated poor diagnostic metrics for acute dengue detection, the NS1 antigen RDT had excellent diagnostic parameters, showing promise as a faster alternative for primary diagnosis and routine surveillance of dengue in Southern Nigeria.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of the STANDARD™ Q Dengue DUO rapid diagnostic test in a resource-limited setting: a laboratory-based evaluation in the Republic of Niger.BMC infectious diseases · 2026
- A comparative analysis of rapid diagnostic tests and enzyme-linked immunosorbent assays for dengue diagnosis: a retrospective study in a tertiary care hospital in India.Microbiology spectrum · 2026
- Diagnostic Accuracy of Rapid Diagnostic Tests Versus Enzyme-Linked Immunosorbent Assay (ELISA) Across Major Infectious Diseases: A Systematic Review and Meta-Analysis.Cureus · 2026
- Characterization of acute dengue immune status and serotype surveillance in three regions of Burkina Faso: a hospital-based cross-sectional study.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2026
- Impact of a point-of-care rapid diagnostic test on the dengue diagnostic cascade in an emergency department in a non-endemic setting: A before-after study (RaDDEO).Infectious diseases now · 2026
- Performance and challenges of malaria rapid diagnostic tests in endemic regions of AfricaScientific Reports · 2025