Label-Efficient Segmentation of Lung Adenocarcinoma Whole-Slide Images: A Controlled Comparison of Self-supervised and Semi-supervised Learning.
Hyeseong Ji, Moses Yook, Chan Kwon Jung, In Young Choi
Department of Precision Medicine and Big Data, College of Medicine, The Catholic University of Korea, Seoul, Korea. · Department of Medical Informatics, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Key points
From the paper's conclusion- Under matched conditions, SSL-init offers a practical advantage when pixel-level labels are extremely scarce, whereas Semi-SL becomes preferable with moderate label coverage. Evaluation that combines Dice with relative labeled-data requirements and memory use offers practical guidance for selecting label-efficient segmentation strategies as digital pathology expands in clinical practice.
Abstract
OBJECTIVES: This study compared label-efficient strategies for segmenting lung adenocarcinoma whole-slide images (WSIs) using a matched protocol. Self-supervised pretraining followed by fine-tuning (SSL-init) using momentum contrast v2, semi-supervised learning (Semi-SL) using Mean Teacher, and a fully supervised baseline were systematically evaluated with the same architecture, input resolution, data augmentations, and evaluation conditions. METHODS: The analysis included 35 WSIs containing 80 tumor regions of interest (ROIs) across six histological subtypes. Models were trained on 1,024 × 1,024 tiles with labeled-tile fractions of f ∈ {10, 15, 20, 30, 40, 50}%. Predictions were aggregated at the ROI level using an operating threshold fixed on the validation set. Performance was evaluated using the Dice coefficient and intersection over union (IoU), together with a relative label-efficiency proxy and peak graphics processing unit memory use. RESULTS: With extremely limited labeling, SSL-init achieved higher and more stable Dice coefficients than Semi-SL at f10 (0.761 ± 0.095) and f15 (0.774 ± 0.084), compared with 0.464 ± 0.402 and 0.546 ± 0.314, respectively, for Semi-SL. From f20 onward, mean Dice was higher for Semi-SL than for SSL-init and approached the fully supervised reference value of 0.886 ± 0.029, reaching 0.858 ± 0.034 at f40 and 0.857 ± 0.041 at f50. IoU followed the same trends. CONCLUSIONS: Under matched conditions, SSL-init offers a practical advantage when pixel-level labels are extremely scarce, whereas Semi-SL becomes preferable with moderate label coverage. Evaluation that combines Dice with relative labeled-data requirements and memory use offers practical guidance for selecting label-efficient segmentation strategies as digital pathology expands in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-supervised pretraining for dermoscopic lesion segmentation with limited labels: A controlled comparison of initialisation strategiesmedRxiv · 2026
- Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label RegimesarXiv · 2026
- Supervised vs. adversarially pre-trained pseudo-label generators for semi-supervised breast cancer patch classification.Frontiers in artificial intelligence · 2026
- Gradient-Based Self-supervised Multi-task Optimization for Weakly Supervised Brain Tumor Segmentation.Journal of imaging informatics in medicine · 2026
- SOTS: Leveraging Self-supervised Pretraining for Label-Efficient Ovarian Tumor Segmentation in Ultrasound Images.Journal of imaging informatics in medicine · 2026
- Superpixel-graph self-supervised pretraining with joint-embedding and contrastive objectives for wound image segmentationAdvances in Science and Technology – Research Journal · 2026