A semi-rapid deployment workflow to reduce device time in Evolut FX self-expanding transcatheter aortic valve implantation.
Shinichiro Doi, Hiroshi Iwata, Eiichiro Sato, Norihito Takahashi, Tomohiro Kaneko, Yui Okada Nozaki, Daisuke Uchiyama, Shinya Okazaki,
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan. · Department of Cardiovascular Surgery, Juntendo University Graduate School of Medicine, Tokyo, Japan.
Key points
From the paper's conclusion- Semi-rapid pacing-assisted Evolut FX deployment selectively reduced device time without compromising early in-hospital safety outcomes. Deployment efficiency represents a practical procedural target for workflow refinement in self-expanding TAVI.
Abstract
BACKGROUND: As transcatheter aortic valve implantation (TAVI) expands, improving deployment efficiency is increasingly important. We developed and implemented a semi-rapid pacing-assisted deployment workflow for the Evolut platform. AIMS: We sought to evaluate the procedural efficiency and early safety of this workflow for transfemoral (TF) Evolut FX TAVI. METHODS: In a single-centre registry, we performed a retrospective before-and-after analysis of consecutive TF Evolut FX procedures: semi-rapid deployment (n=48) versus conventional deployment (n=53). Device time was defined as the interval from initial advancement of the delivery system to final release of the Evolut FX valve. Prolonged device time was defined as >14 minutes (>75th percentile), and determinants were assessed using Firth's penalised logistic regression. RESULTS: The device time was shorter with semi-rapid deployment (9.0 [interquartile range [IQR] 6.0-13.0] minutes vs 14.0 [IQR 11.0-16.0] minutes; p<0.001), while operation and procedure times were similar (p=0.13 and p=0.16, respectively). The mean recapture count was higher in the semi-rapid group (0.85±1.09 vs 0.53±0.70; p=0.08), and contrast volume was higher (32.0 [IQR 25.0-42.0] mL vs 25.0 [IQR 15.0-33.0] mL; p=0.008). Paravalvular leak >=mild (31.2% vs 32.1%; p=1.0) and in-hospital pacemaker implantation (2.1% vs 7.5%; p=0.37) did not differ significantly between the groups. In multivariable analysis, recapture predicted a prolonged device time (adjusted odds ratio [OR] 4.74, 95% confidence interval [CI]: 1.75-14.19; p=0.002), whereas the semi-rapid workflow predicted a reduced device time (adjusted OR 0.10, 95% CI: 0.01-0.66; p=0.015). CONCLUSIONS: Semi-rapid pacing-assisted Evolut FX deployment selectively reduced device time without compromising early in-hospital safety outcomes. Deployment efficiency represents a practical procedural target for workflow refinement in self-expanding TAVI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes of left ventricular pacing with a pre-shaped guidewire during transcatheter aortic valve implantation.REC, interventional cardiology · 2026
- Rapid-Deployment Versus Sutured Aortic Valve Replacement Through Right Anterior Thoracotomy: A Single-Team Retrospective Comparison of Operative Efficiency in 192 Consecutive Patients.Life (Basel, Switzerland) · 2026
- Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self-Expanding Devices: The CONNAVIPRO Study.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Pooled Periprocedural and Short-Term Outcomes After Transcatheter Aortic Valve Replacement With Contemporary Self-Expanding Valves: A Systematic Review and Meta-Analysis.Structural heart : the journal of the Heart Team · 2026
- Machine Learning Models for Predicting Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Scoping Review.Cardiology in review · 2026
- Perioperative outcomes after aortic valve replacement via right anterior mini-thoracotomy with a rapid-deployment valve: a consecutive single-centre seriesFrontiers in Cardiovascular Medicine · 2026