AsiaIntervention

Dedicated versus off-label transcatheter devices for pure native aortic regurgitation via transfemoral access: a meta-analysis of contemporary outcomes.

Joshua J Hon, Archie Egrilmezer, Jimmy K F Hon

Faculty of Medicine, Imperial College London, London, United Kingdom. · Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.

Meta-analysis

Key points

From the paper's conclusion
  • In contemporary transfemoral TAVI for PNAR, dedicated devices demonstrated superior procedural outcomes compared with off-label devices. These findings support the preferential use of dedicated devices in this population, though randomised trials are needed to establish definite treatment recommendations.

Abstract

BACKGROUND: Pure native aortic regurgitation (PNAR) poses unique technical challenges for transcatheter aortic valve implantation (TAVI), including annular dilatation and absent calcification for anchoring. Whilst dedicated aortic regurgitation (AR) devices have been developed, their comparative performance against off-label devices specifically via transfemoral access - the contemporary standard approach - remains incompletely defined. AIMS: We aimed to compare the outcomes of dedicated versus off-label transcatheter devices for PNAR via transfemoral access in contemporary practice. METHODS: We systematically searched PubMed (MEDLINE) and Cochrane CENTRAL (January 2020-November 2025) for studies reporting transfemoral TAVI outcomes in PNAR. The primary outcome was 30-day mortality. Random-effects meta-analysis with meta-regression was performed. RESULTS: Twenty-four studies (2,956 patients) were included comprising 25 cohorts: 4 cohorts (537 patients) evaluated dedicated devices, and 21 cohorts (2,419 patients) assessed off-label devices. Overall, 30-day mortality was 3.3% (95% confidence interval [CI]: 2.3-4.8%). Dedicated devices showed a trend towards lower mortality (1.9% vs 4.1%, odds ratio [OR] 0.45, 95% CI: 0.20-1.00; p=0.051; risk ratio 0.40, 95% CI: 0.19-0.83). Dedicated devices achieved higher device success (95.8% vs 85.7%, OR 3.64; p=0.012), lower rates of residual AR >=moderate (0.6% vs 6.2%, OR 0.11; p=0.048), reduced valve embolisation (2.0% vs 7.3%, OR 0.26; p=0.048), and fewer reinterventions (2.0% vs 7.9%, OR 0.22; p=0.010). Permanent pacemaker implantation (20.8%), stroke (2.6%), and major bleeding (3.0%) were similar between groups. CONCLUSIONS: In contemporary transfemoral TAVI for PNAR, dedicated devices demonstrated superior procedural outcomes compared with off-label devices. These findings support the preferential use of dedicated devices in this population, though randomised trials are needed to establish definite treatment recommendations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Dedicated versus off-label transcatheter devices for pure native aortic regurgitation via transfemoral access: a meta-analysis of contemporary outcomes — Science Skim