Angiographic and functional assessment after paclitaxel or sirolimus drug-coated balloons for de novo coronary artery disease in small vessels: PICCOLETO VI study
Simone Fezzi, Mauro Gitto, Aurora Trevisanello, Faisal Sharif, Gabriele Venturi, Jacek Bezubka, Sylwia Iwanczyk, Wojciech Wanha,
University of Verona · Humanitas University
Key points
From the paper's conclusion- A μFR <=0.86 following drug-coated balloon (DCB) treatment emerged as a reliable cutoff for predicting follow-up ischaemia, with an accuracy of 80%, whereas no significant interaction was observed for a post-DCB angiographic degree of stenosis >=30%.
Abstract
Background: Paclitaxel-coated balloons (PCB) have strong supporting evidence for use in small coronary vessels, while sirolimus-coated balloons (SCB) have shown variable angiographic results, raising questions about their overall effectiveness. Aims: coronary artery disease. Methods: This international, multicentre study included patients who underwent percutaneous coronary intervention and had elective angiographic follow-up 5-9 months later. Angiographic and physiological assessments were performed by a core laboratory, including Murray law-based quantitative flow ratio (μFR). Results: Based on a cohort of 293 patients, 227 lesions treated either with a PCB (n=148) or an SCB (n=79) were included. No differences in terms of baseline clinical or angiographic characteristics were reported between the two cohorts. PCB showed lower late lumen loss (-0.05±0.56 mm vs +0.10±0.59 mm; p=0.05) and a higher prevalence of late lumen enlargement (58.1% vs 40.5%; p=0.01). The primary endpoint of late functional loss was not statistically different, with a trend in favour of PCB (-0.01±0.15 vs +0.03±0.13; p=0.09). There was no difference in terms of target lesion failure, with a higher rate of ischaemia-inducing vessels at follow-up in the SCB group (14.9% vs 26.6%; p=0.03). A μFR <=0.86 following drug-coated balloon (DCB) treatment emerged as a reliable cutoff for predicting follow-up ischaemia, with an accuracy of 80%, whereas no significant interaction was observed for a post-DCB angiographic degree of stenosis >=30%. Conclusions: In this direct comparison between two classes of DCB, late functional loss was comparable between PCB and SCB, with PCB confirming superior angiographic performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Low-dose versus regular-dose paclitaxel-coated balloons for de novo coronary lesions: the ALLIANCE registry.Cardiovascular intervention and therapeutics · 2026
- Drug-coated balloons in coronary disease: meta-analysis comparing sirolimus- and paclitaxel-coated technologies.BMC cardiovascular disorders · 2026
- Sirolimus- vs. paclitaxel-coated balloons in peripheral arterial disease: a propensity score matched analysis from the real-world RECCORD registryEuropean Heart Journal · 2026
- Safety and efficacy of drug-eluting balloons in large coronary vessels: a lesion-level analysis of real-world PCI practiceEuropean Heart Journal · 2026
- Evaluating drug-coated balloon versus drug-eluting stent for the treatment of small coronary artery disease: a meta-analysis and systematic review.Frontiers in cardiovascular medicine · 2026
- Paclitaxel-Coated Balloon for Coronary In-Stent Restenosis and De Novo Disease in Chinese PatientsJACC Asia · 2026