Cancer research and treatment

A Nationwide Study of Interobserver Agreement and Accuracy in HER2 Immunohistochemistry and the Impact of Artificial Intelligence on HER2 Interpretation.

Hyunwoo Lee, Gyu Young Kim, Yoon Ah Cho, Gyungyub Gong, Hee Jin Lee, Byung-Kwan Jeong, Ji-Seon Jeong, Young Kyung Bae,

Department of Pathology and Translational Genomics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. · Medical Affairs, AIVIS Inc., Seoul, Korea.

Observational

Key points

From the paper's conclusion
  • AI-assisted assessment improved the reproducibility and diagnostic performance of HER2 interpretation, with the greatest benefit observed in clinically relevant HER2 low-expression categories. The reduced interpretation time in HER2-ultralow BCs further suggests that AI can improve efficiency in diagnostically challenging cases encountered in routine practice.

Abstract

PURPOSE: Accurate assessment of low levels of human epidermal growth factor receptor 2 (HER2) expression has become increasingly important with the expansion of HER2-targeted therapies to patients with HER2-low and HER2-ultralow breast cancer (BC). Following the introduction of revised College of American Pathologists (CAP) guidelines incorporating the HER2-ultralow (0+) category, we conducted a nationwide multireader study to evaluate interobserver variation in HER2 interpretation and to investigate the impact of artificial intelligence (AI)-assisted image analysis. MATERIALS AND METHODS: A total of 168 BC cases stained using the VENTANA HER2 (4B5) assay were digitized as whole-slide images (WSIs). Thirty-four board-certified breast pathologists independently reviewed all cases without AI assistance and repeated the assessment after a four-week washout period using AI support. Interobserver agreement, classification performance, and reading time were compared between the two phases. RESULTS: AI assistance significantly improved interobserver agreement (Krippendorff's alpha, 0.7415 to 0.8849; Fleiss' kappa, 0.4492 to 0.7524; p<0.001). The largest gains in diagnostic performance were observed in HER2-ultralow and HER2 IHC 1+ BCs, with sensitivities improving from 48.5% to 73.9% and from 64.9% to 87.7%, respectively (p<0.001). Although overall reading time was not reduced in the unadjusted analysis, AI assistance shortened interpretation time in HER2-ultralow BCs by 3.12 seconds (5.1% reduction). CONCLUSION: AI-assisted assessment improved the reproducibility and diagnostic performance of HER2 interpretation, with the greatest benefit observed in clinically relevant HER2 low-expression categories. The reduced interpretation time in HER2-ultralow BCs further suggests that AI can improve efficiency in diagnostically challenging cases encountered in routine practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers