Journal of pathology and translational medicine

Utility of LymphoTrack for clonality testing in formalinfixed, paraffin-embedded tissue: integrated panel- and specimen-level comparison with fragment analysis.

Ki-Chang Lee, Hyun-A Kim, Jiwon Koh, Jeong Mo Bae, Cheol Lee, Seung Geun Song, Yoon Kyung Jeon

Department of Pathology, Seoul National University Hospital, Seoul, Korea. · Field Application Specialist Team, Dow Biomedica Inc., Seoul, Korea.

Key points

From the paper's conclusion
  • LymphoTrack showed high specimen-level agreement with fragment analysis despite panel-specific technical vulnerability in FFPE tissue. Partial panel failure had asymmetric implications: a Positive panel preserved a monoclonal interpretation, whereas polyclonal results with incomplete panel coverage remained vulnerable to discordance. Reporting incomplete panel coverage may help communicate this limitation.

Abstract

BACKGROUND: Next-generation sequencing-based clonality assays provide sequence-level resolution but remain vulnerable to panel-specific failure in formalin-fixed, paraffin-embedded (FFPE) tissue. We evaluated LymphoTrack performance and integrated multi-panel interpretation. METHODS: Seventeen FFPE specimens from 16 patients underwent 51 immunoglobulin heavy-chain (IGH) and 12 T-cell receptor (TCR) panel runs. Results were classified as Positive, Negative, or Fail and compared with lineage-level fragment-analysis interpretations. Panels targeting each lineage were integrated into specimen-level interpretations. Quality-control metrics associated with panel failure were explored. RESULTS: Among 51 IGH panel runs, 37 (72.5%) were concordant, four (7.8%) discordant, and 10 (19.6%) Fail; all Fail results occurred in FR1 or FR2. IGH specimen-level agreement was 16/17 (94.1%; 95% confidence interval [CI], 73.0% to 99.0%). LymphoTrack classified four IGH specimens as monoclonal and 13 as polyclonal, including six based on incomplete panel coverage. One such specimen (FR1/FR2 Fail and FR3 Negative) was discordant with monoclonal fragment analysis. TCR specimen-level agreement was 5/6 (83.3%; 95% CI, 43.6% to 97.0%). In the discordant TCR specimen, T-cell receptor gamma (TRG) fragment analysis was oligoclonal, whereas both LymphoTrack TRG and T-cell receptor beta were Positive. A post-polymerase chain reaction library concentration threshold of ≤4.5 ng/μL identified all Fail panels but had limited specificity (58.5%) and precision (31.3%). CONCLUSIONS: LymphoTrack showed high specimen-level agreement with fragment analysis despite panel-specific technical vulnerability in FFPE tissue. Partial panel failure had asymmetric implications: a Positive panel preserved a monoclonal interpretation, whereas polyclonal results with incomplete panel coverage remained vulnerable to discordance. Reporting incomplete panel coverage may help communicate this limitation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers