Nigerian journal of clinical practice

Large Language Model Prediction of Subsequent Ultrasound BI-RADS Categories from Pre-Imaging Clinical Information in Symptomatic Breast Patients: An Exploratory Retrospective Study.

O Ozyigit, E Yildirim, S Durmus, M A Youshanlui, H Uzun

Department of Radiology, Faculty of Medicine, Istanbul Atlas University, Istanbul, Turkiye. · Department of General Surgery, Faculty of Medicine, Istanbul Atlas University, Istanbul, Turkiye.

Observational · n=120

Key points

From the paper's conclusion
  • LLM-based prediction from pre-imaging clinical information showed limited agreement with subsequent US BI-RADS categorization. Although the clinical-only workflow had numerically higher performance than the clinical-plus-physical-examination workflow, the difference was not statistically significant. Neither workflow demonstrated sufficient sensitivity to support standalone rule-out, imaging deferral, or clinical triage. These exploratory findings require validation in larger prospective cohorts.

Abstract

BACKGROUND: Artificial intelligence (AI) has shown promising performance in image-based breast lesion analysis, but the ability of large language models (LLMs) to predict subsequent ultrasound (US) BI-RADS categorization from pre-imaging clinical information remains less well characterized. AIM: This exploratory study evaluated whether an LLM could predict subsequent US BI-RADS categories using clinical information and whether the addition of physical examination findings altered predictive performance. METHODS: This retrospective single-center exploratory study included 120 women with breast-related complaints who underwent breast ultrasonography. Two LLM-based workflows were evaluated: a clinical-only workflow and a clinical-plus-physical-examination workflow. US BI-RADS served as the imaging reference outcome. Agreement was assessed using unweighted and quadratic weighted Cohen's κ. Prediction of US BI-RADS ≥4 was evaluated using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), balanced accuracy, and area under the receiver operating characteristic curve (AUC), with 95% confidence intervals (CIs). The workflows were compared using paired DeLong and McNemar tests. Exploratory predictors of US BI-RADS ≥4 were evaluated using Firth penalized logistic regression. RESULTS: Nine of 120 patients (7.5%) had US BI-RADS ≥4. For the clinical-only workflow, unweighted κ was 0.198 (95% CI, 0.056-0.338) and quadratic weighted κ was 0.304 (95% CI, 0.070-0.500); corresponding values for the clinical-plus-physical-examination workflow were 0.014 (95% CI, -0.105-0.135) and 0.241 (95% CI, 0.034-0.413), respectively. Sensitivity for US BI-RADS ≥4 was 55.6% (95% CI, 21.2-86.3) and 33.3% (95% CI, 7.5-70.1), while NPV was 96.3% (95% CI, 90.8-99.0) and 94.3% (95% CI, 88.0-97.9) for the clinical-only and clinical-plus-physical-examination workflows, respectively. AUCs were 0.748 (95% CI, 0.519-0.977) and 0.643 (95% CI, 0.409-0.877), with no significant difference between workflows (paired DeLong P = 0.291; McNemar P = 0.579). In exploratory Firth regression, the presence of a hard palpable lesion was associated with US BI-RADS ≥4 (adjusted OR, 11.67; 95% CI, 1.77-75.95; P = 0.013). CONCLUSION: LLM-based prediction from pre-imaging clinical information showed limited agreement with subsequent US BI-RADS categorization. Although the clinical-only workflow had numerically higher performance than the clinical-plus-physical-examination workflow, the difference was not statistically significant. Neither workflow demonstrated sufficient sensitivity to support standalone rule-out, imaging deferral, or clinical triage. These exploratory findings require validation in larger prospective cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers