Comparison of Choroidal Vascular Index Measurements in Pachychoroid Pigment Epitheliopathy using Manual ImageJ-Based Niblack and Protocol-Standardized Otsu Thresholding.
Doğukan Cömerter
Department of Ophthalmology, Sultan Abdülhamid Han Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Key points
From the paper's conclusion- Protocol-standardized Otsu thresholding yielded CVI measurements that were directionally consistent with manual ImageJ-based Niblack analysis in PPE when a full-length choroidal ROI strategy was applied. This approach may support standardized group-level research analyses, but it should not be interpreted as establishing accuracy equivalence or full clinical interchangeability.
Abstract
PURPOSE: To compare choroidal vascular index (CVI) measurements obtained using manual ImageJ-based Niblack thresholding and protocol-standardized Otsu thresholding in patients with pachychoroid pigment epitheliopathy (PPE), employing a full-length choroidal region of interest (ROI) approach. METHODS: This retrospective observational study included 30 eyes of 30 patients diagnosed with PPE. Enhanced depth imaging-optical coherence tomography (EDI-OCT) scans were acquired using Heidelberg Spectralis. Both horizontal and vertical fovea-centered B-scans were analyzed. The ROI was manually delineated on the OCT device using the polygon selection tool to include the entire visible choroid from the retinal pigment epithelium/Bruch's membrane complex to the choroidoscleral junction across the full scan width. CVI was calculated as the ratio of luminal area-to-total choroidal area. Manual ImageJ-based Niblack local thresholding was compared with protocol-standardized Otsu global thresholding using identical manually defined ROIs. Agreement was evaluated using paired t-tests, Pearson correlation, intraclass correlation coefficient (ICC), and Bland-Altman analysis. RESULTS: A total of 60 OCT B-scans were analyzed. Mean CVI values were 0.615 ± 0.030 for ImageJ-Niblack and 0.626 ± 0.052 for Otsu thresholding. The mean intermethod difference was +0.011 ± 0.028, with no statistically significant difference between methods (P = 0.085). A strong linear association was observed (r = 0.90, P < 0.001), and ICC (2,1) demonstrated good agreement (0.76). Bland-Altman analysis showed a small mean bias (+0.012) with 95% limits of agreement from -0.049 to +0.073. Because no external reference standard or prespecified clinical equivalence margin was available, the findings support methodological consistency rather than interchangeability or accuracy equivalence. CONCLUSIONS: Protocol-standardized Otsu thresholding yielded CVI measurements that were directionally consistent with manual ImageJ-based Niblack analysis in PPE when a full-length choroidal ROI strategy was applied. This approach may support standardized group-level research analyses, but it should not be interpreted as establishing accuracy equivalence or full clinical interchangeability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Optical Coherence Tomography Scan Pattern and Chorio-Scleral Interface Delineation on Choroidal Vascularity Index Measurements.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Choroidal vascularity index changes in proliferative and nonproliferative macular telangiectasia type 2.Taiwan journal of ophthalmology · 2026
- Agreement of VCDR measurements: ultra-widefield imaging versus standard fundus photography compared to BMO-OCTA.BMC ophthalmology · 2026
- Regional and Temporal Changes in Choroidal Vascularity after Panretinal Photocoagulation in Diabetic Retinopathy: A Widefield SS-OCTA Study.Retina (Philadelphia, Pa.) · 2026
- Choroidal changes in psoriatic arthritis assessed by optical coherence tomography: a cross-sectional study.International ophthalmology · 2026
- Topographic analysis of choroidal thickness in pachychoroid disease using ultra-widefield swept-source optical coherence tomography.The British journal of ophthalmology · 2026