Journal of cytology

The International System for Reporting Serous Fluid Cytopathology: The Need for Version 2.0.

Padmini C Vijayasarathy, Shanmugapriya Shankar, Anil K Sirasagi, Chinmayi Saravanane

Department of Pathology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India. · Department of Pathology, ESIC Medical College and PGIMSR, Bengaluru, Karnataka, India.

Observational

Key points

From the paper's conclusion
  • TIS is a standardized and efficient approach in categorizing serous body fluids. Due to the close ROM observed in the AUS and SFM categories, there lies a scope for finer refinement of the criteria for the AUS category.

Abstract

BACKGROUND: Serous effusion cytopathology, of neoplastic and non-neoplastic origin, when feasible, should be coupled with ancillary procedures for the detection of malignancies. "The International System for Reporting Serous Fluid Cytopathology" (TIS) categorizes into nondiagnostic (ND), negative for malignancy (NFM), atypical cells of undetermined significance (AUS), suspicious for malignancy (SFM), and malignant (MAL) categories to establish better communication between pathologists and clinicians. AIMS: This study aimed to reclassify the serous body fluids according to TIS and assess their risk of malignancy (ROM). MATERIALS AND METHODS: A retrospective cross-sectional study was conducted in the Department of Pathology for a period of 4.5 years after obtaining clearance from the Institutional Ethics Committee. Serous effusions, having corresponding cell block or tissue biopsy, were recategorized as per the TIS, and ROM was calculated for all categories. Continuous variables were represented as ranges, medians, and means. Analysis of variance (ANOVA) and chi-square tests were used to analyze the distribution of continuous variables as per the TIS category. RESULTS: This study included 370 fluids. The majority (224 samples, 60.5%) comprised ascitic fluid, followed by 136 pleural fluids (36.7%). ND, NFM, AUS, SFM, and MAL categories had 7 (1.89%) cases, 285 (77%) cases, 6 (1.62%) cases, 15 (4.05%) cases, and 57 (15.4%) cases with ROM of 14.28%, 10.82%, 83.33%, 86.66%, and 100.00%, respectively. ANOVA and chi-square tests showed a P value of 0.002. CONCLUSIONS: TIS is a standardized and efficient approach in categorizing serous body fluids. Due to the close ROM observed in the AUS and SFM categories, there lies a scope for finer refinement of the criteria for the AUS category.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

The International System for Reporting Serous Fluid Cytopathology: The Need for Version 2.0 — Science Skim