The International System for Reporting Serous Fluid Cytopathology: The Need for Version 2.0.
Padmini C Vijayasarathy, Shanmugapriya Shankar, Anil K Sirasagi, Chinmayi Saravanane
Department of Pathology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India. · Department of Pathology, ESIC Medical College and PGIMSR, Bengaluru, Karnataka, India.
Key points
From the paper's conclusion- TIS is a standardized and efficient approach in categorizing serous body fluids. Due to the close ROM observed in the AUS and SFM categories, there lies a scope for finer refinement of the criteria for the AUS category.
Abstract
BACKGROUND: Serous effusion cytopathology, of neoplastic and non-neoplastic origin, when feasible, should be coupled with ancillary procedures for the detection of malignancies. "The International System for Reporting Serous Fluid Cytopathology" (TIS) categorizes into nondiagnostic (ND), negative for malignancy (NFM), atypical cells of undetermined significance (AUS), suspicious for malignancy (SFM), and malignant (MAL) categories to establish better communication between pathologists and clinicians. AIMS: This study aimed to reclassify the serous body fluids according to TIS and assess their risk of malignancy (ROM). MATERIALS AND METHODS: A retrospective cross-sectional study was conducted in the Department of Pathology for a period of 4.5 years after obtaining clearance from the Institutional Ethics Committee. Serous effusions, having corresponding cell block or tissue biopsy, were recategorized as per the TIS, and ROM was calculated for all categories. Continuous variables were represented as ranges, medians, and means. Analysis of variance (ANOVA) and chi-square tests were used to analyze the distribution of continuous variables as per the TIS category. RESULTS: This study included 370 fluids. The majority (224 samples, 60.5%) comprised ascitic fluid, followed by 136 pleural fluids (36.7%). ND, NFM, AUS, SFM, and MAL categories had 7 (1.89%) cases, 285 (77%) cases, 6 (1.62%) cases, 15 (4.05%) cases, and 57 (15.4%) cases with ROM of 14.28%, 10.82%, 83.33%, 86.66%, and 100.00%, respectively. ANOVA and chi-square tests showed a P value of 0.002. CONCLUSIONS: TIS is a standardized and efficient approach in categorizing serous body fluids. Due to the close ROM observed in the AUS and SFM categories, there lies a scope for finer refinement of the criteria for the AUS category.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of The International System for Serous Fluid Cytopathology to cerebrospinal fluid and adjunct flow cytometry analysis improves diagnostic accuracyCancer Cytopathology · 2026
- Diagnostic Efficacy of the International System for Reporting Serous Fluid Cytopathology Classification in Pleural Effusion Samples to Analyze the Risk of Malignancy Associated with Each Category and Explore the Prognostic Significance of the Systemic Immune-Inflammation Index within These Classifications.Journal of cytology · 2026
- Update on the impact of volume and cellularity on serous fluids: Nondiagnostic definitions and criteria for the upcoming International System v2Cancer Cytopathology · 2026
- Application of the International System for Serous Fluid Cytopathology in cerebrospinal fluid cytology: Overall survival analysis associated with diagnostic categoriesCancer Cytopathology · 2026
- Diagnostic Accuracy of Soft Tissue Cytology and Risk of Malignancy Across the IAC-IARC-WHO Six-Tier Reporting System: A Systematic Review and Meta-Analysis With Retrospective Category Mapping.Diagnostic cytopathology · 2026
- Validation of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Cytopathology.Cureus · 2026