Comparative evaluation of postfabrication thickness of thermoformed 3 mm and 4 mm mouthguards on crowded and proclined malocclusion models: An in vitro study.
Ritesh Kalaskar, Nidhi Sharma, Ashita Kalaskar
Department of Paediatric and Preventive Dentistry and Oral Medicine and Radiology, Government Dental College and Hospital, Nagpur, Maharashtra, India.
Key points
From the paper's conclusion- Thermoforming causes substantial reduction in mouthguard thickness, particularly in anterior regions. Dental alignment influences final thickness, and clinicians should consider postfabrication thinning when selecting EVA sheet thickness to ensure adequate protection.
Abstract
PURPOSE: To evaluate and compare the postfabrication thickness (PFT) of thermoformed mouthguards fabricated from 3 mm and 4 mm ethylene-vinyl acetate (EVA) sheets on crowded and proclined dental models. MATERIALS AND METHODS: An in-vitro study was conducted using 20 mouthguards fabricated on dental stone models with crowded and proclined maxillary anterior teeth. Pressure-molded mouthguards were made using 3 mm and 4 mm EVA sheets. PFT was measured at standardized labial, buccal, and sulcus regions using an Iwanson caliper. Statistical analysis was performed using ANOVA, Tukey's post hoc test, and unpaired t -test ( P < 0.05). RESULTS: Significant thickness reduction was observed in both 3 mm and 4 mm mouthguards. In crowded dentition, 42%-61% thinning occurred at labial surfaces and 53%-71% at the sulcus, while proclined dentition showed 40%-60% and 51%-67% thinning, respectively. Maximum thinning occurred at canines, whereas molars showed the least reduction. CONCLUSION: Thermoforming causes substantial reduction in mouthguard thickness, particularly in anterior regions. Dental alignment influences final thickness, and clinicians should consider postfabrication thinning when selecting EVA sheet thickness to ensure adequate protection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of 3D-printed model base height on thickness distribution of thermoformed zendura FLX dual-layer clear aligners: an in vitro study.Frontiers in dental medicine · 2026
- Does Thermoforming Setup Affect Thickness in Thermoplastic Orthodontic Appliances? A Comparison of Single vs. Dual-Model Fabrication.Polymers · 2026
- Effect of Different Ethylene-Vinyl Acetate (EVA) Brands Used for Customized Mouthguards on Athlete Preferences, Wearability, Willingness to Pay, Clinical Performance, and Structural Deformation in Elite Soccer Players: A Randomized Double-Blind Crossover Clinical Trial.Dental traumatology : official publication of International Association for Dental Traumatology · 2026
- Impact Absorption on 3D Printed Mouthguard Material in Selected Printing Angulations.Dental traumatology : official publication of International Association for Dental Traumatology · 2026
- Custom-Made Versus Non-Custom Mouthguards in the Prevention of Sports-Related Oro-Dento-Facial Trauma: A Scoping Review of the Clinical Evidence.Bioengineering (Basel, Switzerland) · 2026
- Semi-Digital and Conventional Protocols for Masking Orthodontic Appliances and Fabricating Customized Mouthguards: A Step-by-Step Clinical Guide.Dental traumatology : official publication of International Association for Dental Traumatology · 2026