Key points
From the paper's conclusion- Within the limitations of a single patient-specific model and the absence of inferential statistical analysis, this single-case biomechanical evaluation suggests that digital twin-based finite element analysis may serve as an exploratory tool for biomechanical assessment and prosthodontic treatment planning in implant-supported rehabilitation of the edentulous maxilla.
Abstract
AIM: Finite element analysis (FEA) is widely used in implant prosthodontics to assess biomechanical behavior and support treatment planning in complex edentulous cases. This work aimed to evaluate stress distribution patterns associated with three implant configurations (all-on-four, all-on-six, and quad-zygomatic) in the edentulous maxilla using a single patient-specific finite element model under immediate loading conditions. SETTINGS AND DESIGN: Two CBCT scans from a single edentulous patient, acquired before and after full-arch bone grafting, were segmented to generate three digital twin models including the maxilla, implants, abutments, and a full-arch prosthesis. MATERIALS AND METHODS: A unilateral oblique load of 150 N at 45° was applied to the posterior region of the prosthesis using a non-deformable distribution tool to simulate immediate functional loading. Stress distribution and displacement patterns within bone and prosthetic components were evaluated. STATISTICAL ANALYSIS USED: A descriptive biomechanical evaluation based on stress magnitude and distribution patterns was conducted. RESULTS: The simulations demonstrated distinct biomechanical responses among the implant configurations. The all-on-six model showed a more uniform stress distribution with lower peak stress values compared to the other configurations. In this model, the difference between tensile and compressive cortical stress peaks was reduced relative to the all-on-four and quad-zygomatic configurations. In all scenarios, stress values remained within physiological limits reported for bone tissue. CONCLUSION: Within the limitations of a single patient-specific model and the absence of inferential statistical analysis, this single-case biomechanical evaluation suggests that digital twin-based finite element analysis may serve as an exploratory tool for biomechanical assessment and prosthodontic treatment planning in implant-supported rehabilitation of the edentulous maxilla.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Interaction Between Endosseous and Patient-Specific Subperiosteal Implants in Full-Arch Rehabilitation of the Atrophic Maxilla: A Finite Element Analysis.The International journal of oral & maxillofacial implants · 2026
- Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis.Dentistry journal · 2026
- Finite element analysis of stress distribution in zygomatic implant configurations with different hybrid prosthesis superstructure materialsScientific Reports · 2026
- Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous MandibleClinical Implant Dentistry and Related Research · 2026
- Bite Force Analysis Using Numerical Simulation with Different Prosthesis Anchorages.Biomimetics (Basel, Switzerland) · 2026
- Posterior Implant Tilt as an Alternative to Sinus Elevation in Full-Arch Maxillary Rehabilitation: A Comparative Finite Element Analysis.Journal of stomatology, oral and maxillofacial surgery · 2026