Assessment of Diffusing Capacity of Lung for Carbon Monoxide (DLCO) in Silica-Exposed Workers.
Shafeena Basheer, Chaina Ram Choudhary, Ashok Kuwal, Lokesh Kumar Gupta, Smruthi Valsalan, Vishram Kumawat, K M Althaf
Department of Respiratory Medicine, Dr SN Medical College, Jodhpur, Rajasthan, India. · Department of Nuclear Medicine, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
Key points
From the paper's conclusion- DLCO can detect lung function impairment in asymptomatic or mildly symptomatic silica-exposed workers.
Abstract
BACKGROUND: Diagnosis of lung diseases associated with silica exposure typically relies on a history of occupational silica dust exposure and chest X-ray. Diffusing capacity of the lung for carbon monoxide (DLCO) is a pulmonary function test that measures the lungs' ability to transfer gas from inspired air to the bloodstream. AIMS: To analyses the role of DLCO in the early detection of lung function impairment in asymptomatic or symptomatic workers exposed to silica dust for 5 years or more. SETTINGS AND DESIGN: An observational study conducted in a tertiary care center of Rajasthan. METHODS AND MATERIALS: A total of 50 silica-exposed workers without a history of Tuberculosis and other pneumoconiosis were enrolled based on inclusion criteria. Each participant underwent a detailed clinical history, physical examination, chest X-ray, hemoglobin, spirometry, and DLCO. STATISTICAL ANALYSIS USED: Pearson and Spearman tests were used for correlation. Categorical data were compared by the Chi-square test, and medians were compared with the Mann-Whitney U test. A P value less than 0.05 was considered significant. RESULTS: The study population had a median age of 44 years, and 90% were male. The median duration of silica exposure was 15.5 years, and the majority were stone-cutters. DLCO and spirometry detected abnormalities in 72% and 52% of the study population, respectively. Notably, more than half (66.6%) of the participants with normal spirometry had impaired DLCO, recommending the addition of DLCO in the surveillance of silica-exposed workers. A significant correlation was observed between the duration of silica exposure and the severity of impairment. CONCLUSIONS: DLCO can detect lung function impairment in asymptomatic or mildly symptomatic silica-exposed workers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Isolated, reduced diffusing capacity for carbon monoxide in the population - relations to symptoms, smoking and comorbidities.BMC pulmonary medicine · 2026
- A Review on Current Challenges and Knowledge Gaps in Artificial Stone Silicosis.American journal of industrial medicine · 2026
- The role of whole lung lavage in pneumoconiosis patients with pulmonary diffusion limitation.Frontiers in medicine · 2026
- Clinical Assessment of Smokers with Persistent Dyspnoea but Unremarkable Spirometry: The Added Value of Diffusing Capacity for Carbon Monoxide.COPD · 2026
- Nailfold Capillaroscopy Patterns Are Associated with Impairment of DLCO in Very Early Diagnosis of Systemic Sclerosis: Insights of a Pulmonary-Vascular Interplay.Diagnostics (Basel, Switzerland) · 2026
- Small-airway function and reduced diffusing capacity in hospitalised adults with preserved baseline spirometry: a retrospective cross-sectional studyBMC Pulmonary Medicine · 2026