Retrospective analysis of indications and outcomes of trabecular micro-bypass stent implantation in Indian eyes.
Amit Pandey, Harsh Kumar, Abhishek Kathuria, Sagarika Patyal, Swati Singh, Bhavini Pandey
Medical City for Military and Security Services, AlKhoudh, Muscat, Oman. · Centre for Sight Eye Hospital, Delhi, India.
Key points
From the paper's conclusion- iStent implantation in Indian eyes demonstrated promising outcomes in reducing both intraocular pressure and anti-glaucoma medication burden. While combined procedures exhibited superior efficacy in reducing IOP and AGM, postoperative complications such as steroid-induced IOP rise were observed, emphasizing the importance of careful monitoring and management in optimizing surgical outcomes.
Abstract
PURPOSE: To analyze the patient characteristics, initial outcomes, and complications associated with iStent implantation in Indian eyes. METHODS: This retrospective case series comprised subjects who underwent iStent, iStent inject, or iStent inject W implantation as a standalone procedure or combined with phacoemulsification with at least 12 months follow-up. The main outcome measures were change in intraocular pressure (IOP) and number of anti-glaucoma medication (AGM), post op complications, and resurgery rates at the final follow-up. RESULTS: A total of 56 eyes of 46 patients were included. Twenty-six eyes received iStent, and 30 eyes received either iStent inject or iStent inject W. Mean IOP reduced by 25.5%, and the mean number of AGM decreased by 75.8% at final follow-up ( P < 0.005). The overall success rate was achieved in 51 eyes (85%). When compared to standalone iStent, combined phacoemulsification with iStent delivered greater reduction in AGM ( P = 0.004). Compared to iStent, eyes with iStent inject and inject W had better IOP reduction ( P = 0.03), lesser AGM ( P < 0.005), and a lesser number of surgical failures ( P = 0.045). Three months after iStent inject implantation, trabeculectomy was performed in one eye with secondary glaucoma. Postoperative IOP rise due to steroid response was observed in 20 eyes (35.7%). CONCLUSION: iStent implantation in Indian eyes demonstrated promising outcomes in reducing both intraocular pressure and anti-glaucoma medication burden. While combined procedures exhibited superior efficacy in reducing IOP and AGM, postoperative complications such as steroid-induced IOP rise were observed, emphasizing the importance of careful monitoring and management in optimizing surgical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Travoprost Intracameral Implant as a Standalone Procedure or Combined with Minimally Invasive Glaucoma Surgery (MIGS).Advances in therapy · 2026
- One-year clinical outcomes of iStent infinite® versus iStent inject® in open-angle glaucoma.Journal francais d'ophtalmologie · 2026
- Evaluation of iStent® Inject W in mild to moderate primary open-angle glaucoma - Indian data on pseudophakic eyes.Indian journal of ophthalmology · 2026
- Efficacy and safety of ELIOS excimer laser trabeculostomy versus iStent inject as an adjunct to phacoemulsification: a retrospective comparative study.The British journal of ophthalmology · 2026
- Preliminary Outcomes of iStent Inject vs Kahook Dual Blade Goniotomy Combined With Phacoemulsification: A Randomized Controlled Trial.Medical science monitor : international medical journal of experimental and clinical research · 2026
- Comparative Outcomes of Stent vs. Non-Stent Trabecular Minimally Invasive Glaucoma Surgeries: A 4-Year Retrospective Propensity-Matched Study.Ophthalmology. Glaucoma · 2026