Epithelial uniformity pattern post topo-guided LASIK - Role of cyclosporine versus standard of care.
Tanvi Suhas Haldipurkar, Smitha S Kumar, Seema Bhosale, Suhas Haldipurkar, Devendra Venkatramani, Sarita Deshpande, Sabyasachi Sengupta
Department of Cataract and Refractive Surgery, Laxmi Eye Hospital and Institute, Panvel, Maharashtra, India.
Key points
From the paper's conclusion- Topo-guided LASIK induces central/paracentral epithelial thickening with reduced uniformity. The EUI is a useful tool to quantify remodeling. Cyclosporine did not significantly enhance epithelial uniformity.
Abstract
PURPOSE: To evaluate epithelial remodeling after topo-guided LASIK using a novel Epithelial Uniformity Index (EUI) and to assess whether topical cyclosporine improves postoperative epithelial uniformity compared to standard care. METHODS: In this retrospective comparative study, we analyzed 122 eyes of 62 patients undergoing topo-guided LASIK, divided into cyclosporine ( n = 60) and non-cyclosporine ( n = 62) groups. Epithelial thickness was measured using spectral-domain optical coherence tomography across four corneal zones (central, inner, middle, outer) preoperatively and at 1, 3, and 6 months. The EUI was calculated as 1 minus standard deviation/mean across 25-point thickness maps; higher EUI indicates greater uniformity. Visual acuity, corneal aberrations, and patient-reported outcomes were assessed. RESULTS: Both groups showed significant epithelial thickening in the central and inner zones, increasing from ~54 μm at baseline to ~59 μm at 6 months ( P < 0.001). The middle zone also thickened by 6 months ( P < 0.05), while the outer zone thinned at 1 month before recovering. No significant intergroup differences were observed ( P > 0.18). EUI declined significantly at 1 month (inner: 0.98 to 0.96; overall: 0.96 to 0.92; P < 0.05) and showed only partial recovery by 6 months, remaining lower than baseline ( P < 0.05), with no significant differences between groups ( P > 0.1). Higher baseline refractive error correlated with greater EUI reduction (r = 0.58, P < 0.001). Lower EUI weakly correlated with worse uncorrected visual acuity and increased coma (both P < 0.05). CONCLUSIONS: Topo-guided LASIK induces central/paracentral epithelial thickening with reduced uniformity. The EUI is a useful tool to quantify remodeling. Cyclosporine did not significantly enhance epithelial uniformity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temporal and spatial patterns of corneal epithelial remodeling following wavefront-guided FS-LASIK and LASEK.International ophthalmology · 2026
- MS-39 Epithelial map-guided versus standard transepithelial photorefractive keratectomy in regular corneas: a randomized contralateral-eye study.Arquivos brasileiros de oftalmologia · 2026
- Anterior segment OCT-based assessment of efficacy of topical cyclosporine in edematous punctal stenosis.International ophthalmology · 2026
- Effect of Adjunctive Topical Cyclosporine A on Ocular Surface Recovery after Pars Plana Vitrectomy: A Prospective Randomized Trial.Ophthalmology and therapy · 2026
- Early Corneal Remodelling Following Topography-Guided Femtosecond LASIK: A Three-Month Retrospective AnalysisINTERNATIONAL JOURNAL OF ALLIED HEALTH SCIENCES · 2026
- Automated quantification of central corneal epithelial thickness for the diagnosis of limbal stem cell deficiency.PloS one · 2026