Indian journal of ophthalmology

Epithelial uniformity pattern post topo-guided LASIK - Role of cyclosporine versus standard of care.

Tanvi Suhas Haldipurkar, Smitha S Kumar, Seema Bhosale, Suhas Haldipurkar, Devendra Venkatramani, Sarita Deshpande, Sabyasachi Sengupta

Department of Cataract and Refractive Surgery, Laxmi Eye Hospital and Institute, Panvel, Maharashtra, India.

Observational · n=122

Key points

From the paper's conclusion
  • Topo-guided LASIK induces central/paracentral epithelial thickening with reduced uniformity. The EUI is a useful tool to quantify remodeling. Cyclosporine did not significantly enhance epithelial uniformity.

Abstract

PURPOSE: To evaluate epithelial remodeling after topo-guided LASIK using a novel Epithelial Uniformity Index (EUI) and to assess whether topical cyclosporine improves postoperative epithelial uniformity compared to standard care. METHODS: In this retrospective comparative study, we analyzed 122 eyes of 62 patients undergoing topo-guided LASIK, divided into cyclosporine ( n = 60) and non-cyclosporine ( n = 62) groups. Epithelial thickness was measured using spectral-domain optical coherence tomography across four corneal zones (central, inner, middle, outer) preoperatively and at 1, 3, and 6 months. The EUI was calculated as 1 minus standard deviation/mean across 25-point thickness maps; higher EUI indicates greater uniformity. Visual acuity, corneal aberrations, and patient-reported outcomes were assessed. RESULTS: Both groups showed significant epithelial thickening in the central and inner zones, increasing from ~54 μm at baseline to ~59 μm at 6 months ( P < 0.001). The middle zone also thickened by 6 months ( P < 0.05), while the outer zone thinned at 1 month before recovering. No significant intergroup differences were observed ( P > 0.18). EUI declined significantly at 1 month (inner: 0.98 to 0.96; overall: 0.96 to 0.92; P < 0.05) and showed only partial recovery by 6 months, remaining lower than baseline ( P < 0.05), with no significant differences between groups ( P > 0.1). Higher baseline refractive error correlated with greater EUI reduction (r = 0.58, P < 0.001). Lower EUI weakly correlated with worse uncorrected visual acuity and increased coma (both P < 0.05). CONCLUSIONS: Topo-guided LASIK induces central/paracentral epithelial thickening with reduced uniformity. The EUI is a useful tool to quantify remodeling. Cyclosporine did not significantly enhance epithelial uniformity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers