Key points
From the paper's conclusion- Slow-coagulation continuous wave diode transscleral cyclophotocoagulation (SC-TSCPC) was evaluated for treating refractory glaucoma.
- Mean intraocular pressure (IOP) decreased significantly postoperatively, with a reduction in glaucoma medications and no significant deterioration in visual acuity.
- Eyes with baseline IOP >30 mmHg had lower success rates and more complications compared with eyes having baseline IOP <30 mmHg.
Abstract
PURPOSE: To evaluate the short-term safety and efficacy of slow-coagulation trans-scleral cyclophotocoagulation (SC-TSCPC) in patients with refractory glaucoma. METHODS: A retrospective study was done on 140 patients (144 eyes) with a diagnosis of refractory glaucoma and vision more than 2/60 with a minimum follow-up of 6 months. All patients underwent SC-TSCPC (800-milliwatt power and 4 seconds duration). The primary outcome measure was surgical success defined as an intraocular pressure (IOP) from 6 to 21 mmHg or ≥20% IOP reduction from the baseline value, no reoperation for glaucoma, and no loss of light perception vision. Secondary outcome measures include percentage of IOP reduction, glaucoma medications, visual acuity, and complications. RESULTS: Mean IOP decreased from 40.97 ± 12.00 mmHg preoperatively to 19.31 ± 9.91 mmHg (mean percentage IOP reduction = 52.9%) at 6 months postoperatively ( P < 0.0001). The number of glaucoma medications also dropped from 3.0 ± 0.89 at baseline to 2.0 ± 1.4 at 6 months ( P = 0.0003). No significant deterioration in visual acuity was observed during 6 months follow-up ( P < 0.0001). The cumulative probabilities of success at 1, 3, and 6 months were 86.1%, 77.4%, and 66.64%, respectively. Eyes with baseline IOP >30 mmHg demonstrated lower success rates, higher postoperative complications, and greater need for additional glaucoma interventions compared with eyes having baseline IOP <30 mmHg. The most common complications observed were uncontrolled IOP and anterior chamber inflammation. Endophthalmitis and retinal detachment were seen in one patient at 6-month follow-up. CONCLUSION: SC-TSCPC may serve as a useful adjunct or temporizing procedure in selected refractory glaucoma patients who are at high risk for invasive glaucoma surgery. Patients with high preoperative IOP required more surgical interventions and also had more complications warranting individualized laser energy settings.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- Slow-coagulation continuous wave diode transscleral cyclophotocoagulation (SC-TSCPC) was evaluated for treating refractory glaucoma.
- Mean intraocular pressure (IOP) decreased significantly postoperatively, with a reduction in glaucoma medications and no significant deterioration in visual acuity.
- Eyes with baseline IOP >30 mmHg had lower success rates and more complications compared with eyes having baseline IOP <30 mmHg.
Readers' thoughts
No reader thoughts yet.
Related papers
- Dose-effectiveness Optimizing in Micropulse Transscleral Cyclophotocoagulation: A Cohort Study in Refractory Glaucoma.Ophthalmology. Glaucoma · 2026
- Long-Term Postoperative Outcomes of Micropulse Transscleral Cyclophotocoagulation (MP-TSCPC) in Patients with Glaucoma.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Trabeculectomy versus Transscleral Cyclophotocoagulation as a Primary Surgical Procedure in Glaucoma: A Multicenter Randomized Controlled Trial.Journal of glaucoma · 2026
- Clinical Efficacy of Ultrasound Cycloplasty for Glaucoma Patients and Pathological Observation on the Ciliary Body in Rabbit Models.Journal of ophthalmology · 2026
- Ultrasound cycloplasty: dynamic efficacy and long-term safety in glaucoma patients from northwest China.Frontiers in medicine · 2026
- Uveoscleral Outflow Enhancement as a Complementary Bio-intervention after Failed Prior Trabecular Outflow Treatment: 12-Month Outcomes of Allograft-reinforced Cyclodialysis in Open Angle GlaucomamedRxiv · 2026