Outcomes of phaco-endocyclophotocoagulation in acute on chronic primary angle closure glaucoma.
Vanita Pathak Ray
Department of Glaucoma, Centre for Sight, Hyderabad, Telangana, India.
Key points
From the paper's conclusion- Phaco-endocyclophotocoagulation is not only effective but also very safe in controlling IOP and reducing topical medications in PACG eyes that present with acute symptoms. Biometric parameters are significantly different in such eyes when compared to PACG controls.
Abstract
PURPOSE: To report the outcomes of endocyclophotocoagulation (ECP) combined with phacoemulsification in primary angle closure glaucoma (PACG) eyes presenting with acute symptoms (A-o-C-PACG) and to compare the biometric characteristics of these eyes with PACG controls. METHODS: Retrospective data collection of consecutive PACG subjects presenting with symptoms of acute angle closure between May 2021 and September 2023. Such subjects were compared to severity-of-glaucoma-matched PACG controls. Only those eyes that underwent phaco-ECP were included. The main outcome measure was intraocular pressure (IOP) and a comparison of biometric parameters between cases and controls. The secondary outcome measures were the number of anti-glaucoma medications (AGMs), best-corrected visual acuity (BCVA), and complications. RESULTS: Fifteen study eyes and 26 PACG controls were included; the mean age was 54.2 ± 7.4 years. The mean IOP (34.6 ± 13.4 mmHg, 95%CI [27.2,42.0]), AGM (4.3 ± 1.2,95%CI [3.6,5.0]), synechial angle closure (3.3 ± 1.0 quadrants, 95%CI [2.7,3.8]), and lens thickness (5.1 ± 0.3, 95%CI [4.9,5.3]) were significantly more, and the anterior chamber depth (2.3 ± 0.3 mm, 95%CI [2.1,2.5]) and relative lens position (0.20 ± 0.01, 95%CI [0.19,0.20]) were significantly less when compared to PACG controls. IOP at the last follow-up postprocedure (mean 18 months) was 12.7 ± 2.3 mmHg, 95%CI [11.4,13.9] on 0.7 ± 0.8, 95%CI [0.2, 1.1], number of AGM ( P < .001). BCVA improved significantly from 0.9 ± 0.7, 95%CI [0.5,1.3], to 0.2 ± 0.3, 95%CI [0.03,0.4]; none had serious sight-threatening complications. CONCLUSION: Phaco-endocyclophotocoagulation is not only effective but also very safe in controlling IOP and reducing topical medications in PACG eyes that present with acute symptoms. Biometric parameters are significantly different in such eyes when compared to PACG controls.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- One-year outcomes of combined phacoemulsification and goniosynechialysis in primary angle-closure glaucoma with cataracts: a multicenter prospective study.Eye and vision (London, England) · 2026
- The Adjunctive Effect of Goniotomy Combined with Phacoemulsification and Goniosynechialysis for Advanced Primary Angle-Closure Glaucoma with 360° Angle Closure: 12-Month Outcomes.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Preoperative Factors Correlating With Intraocular Pressure Reduction after Phacoemulsification in Primary Angle Closure Glaucoma: A Cohort Study.Journal of glaucoma · 2026
- Seventeen-Year Clinical Analysis of Acute Primary Angle-Closure Glaucoma at a Single Japanese Tertiary Center.Cureus · 2026
- Management and outcomes of acute primary angle closure with phacoemulsification: a clinical audit at hospital Tengku Ampuan RahimahMalaysian Journal of Ophthalmology · 2026
- Three-year outcomes of combined surgical peripheral iridectomy, goniosynechialysis and goniotomy for advanced primary angle-closure glaucoma: a multicentre study.The British journal of ophthalmology · 2026