Indian journal of anaesthesia

A randomised trial comparing 80% and 100% inspired oxygen concentrations for time to adequate preoxygenation using end-tidal oxygen concentration targets.

G Venkata Poornima, A Chaitanya Pratyusha, Ch Rama Krishna Prasad, Ramachandran Gopinath, Rama Krishna Ravula, R Sharanya

Department of Anaesthesia, ESIC Medical College, Hyderabad, Telangana, India. · Department of Anaesthesiology, All India Institute of Medical Sciences, Bibinagar, Hyderabad, Telangana, India.

Randomised

Key points

From the paper's conclusion
  • Non-inferiority of FiO2 80% with 100% could not be established within the prespecified margin, though the median time to achieve adequate preoxygenation was comparable.

Abstract

BACKGROUND AND AIMS: Preoxygenation with 100% oxygen is associated with absorption atelectasis. This study compared 80% and 100% fractional inspired oxygen concentration (FiO2) for the time to achieve adequate preoxygenation, defined by end-tidal oxygen (EtO2). Secondary outcomes included the incidence of postoperative atelectasis, proportion of patients requiring more than 3 minutes for preoxygenation, haemodynamic changes, and desaturation. METHODS: Two-hundred patients for general anaesthesia were randomly divided into either Group I or Group S, the intervention and the standard practice groups, and were preoxygenated with 80% and 100% FiO2, respectively. The time taken to reach an EtO2 of 10% below the administered FiO2 was considered the time to adequate preoxygenation. A lung ultrasonography was performed at baseline and again immediately after extubation. Independent t-test or Mann-Whitney U test and the Chi-square test were used for continuous and nominal categorical data, respectively. Non-inferiority was concluded if the lower bound of the confidence interval remained above the predefined non-inferiority margin of -15 seconds. RESULTS: The median preoxygenation time was comparable between groups: 95 s [interquartile range (IQR) 70-133] and 99.5 s (IQR 80.3-140) in Group I and S, respectively (P = 0.484; 95% confidence interval -21 to 11). Non-inferiority was not demonstrated. The effect size was small (r = -0.096), indicating minimal clinical difference. However, atelectasis was significantly higher in Group S (31.9%) compared to Group I (8.6%) (P = 0.002). CONCLUSION: Non-inferiority of FiO2 80% with 100% could not be established within the prespecified margin, though the median time to achieve adequate preoxygenation was comparable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers