Quality control of red cell components in a tertiary blood center: Evaluation of automated separation, leukoreduction, and irradiation.
Sudipta Sekhar Das, Faiza Eram, Diksha Jaiswal, Sourav Mukherjee, Sourav Chowdhury
Department of Transfusion Medicine, Apollo Multispeciality Hospitals, Kolkata, West Bengal, India.
Key points
From the paper's conclusion- RBC components prepared with automated extraction consistently complied with national and international QC benchmarks, supporting safe transfusion practice.
Abstract
BACKGROUND: Quality control (QC) of red blood cell (RBC) components is essential to ensure transfusion safety. Evaluation of hematological and biochemical parameters helps assess the adequacy of processing and modification techniques. This study aimed to evaluate the quality of leukocyte-reduced, leukocyte-depleted, and irradiated RBC units. Objectives included: (i) assessing hemoglobin content and hematocrit; (ii) quantifying residual leukocyte content; (iii) measuring percentage hemolysis and extracellular potassium content in irradiated RBCs; (iv) evaluating sterility; and (v) comparing results with national and international QC standards. MATERIALS AND METHODS: A retrospective study was conducted at a tertiary care blood center from July 2024 to June 2025. Whole blood was processed using TACE II + automated extractors into leukocyte-reduced and leukocyte-depleted RBCs. Irradiation was performed using a linear accelerator. QC testing of 206 RBC units included hemoglobin content, hematocrit, residual leukocyte content, percentage hemolysis, extracellular potassium content, and sterility. RESULTS: Among 13,673 donations, 13,534 were processed into 5401 leukocyte-reduced and 8133 leukocyte-depleted RBCs. QC testing showed leukocyte-reduced RBCs with hematocrit 57.6% ± 4.7%, hemoglobin content 48.9 ± 4.6 gm, and residual leukocyte content 3.3 ± 2.1 × 108. Leukocyte-depleted units had hematocrit 59.7% ± 5.8%, hemoglobin content 49.0 ± 5.4 gm, and residual leukocyte content 2.3 ± 1.9 × 106. Irradiated units showed a percentage hemolysis of 0.93% ± 0.24% and a potassium content of 24.0 ± 6.2 mmol/L. All units were sterile. Over 90% met QC standards. CONCLUSION: RBC components prepared with automated extraction consistently complied with national and international QC benchmarks, supporting safe transfusion practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on the technological process of preparing blood components from under-collected whole blood units.Hematology, transfusion and cell therapy · 2026
- Current Approaches to the Storage, Processing, and Quality Assessment of RBC and Platelet Components: A Narrative Review.Journal of clinical medicine · 2026
- Red cells stored in non-DEHP containers: The effect of washing, irradiation or storage as paediatric units on in vitro quality parameters.Vox sanguinis · 2026
- Improved blood component quality and processing efficiency with a fully automated whole blood preparation system.Transfusion medicine (Oxford, England) · 2026
- Evaluation and application of automated quality control in clinical coagulation testing.Research and practice in thrombosis and haemostasis · 2026
- Effects of washing with different crystalloid solutions on the oxygen delivery capacity and membrane integrity of salvaged erythrocytes: a comparative study in a rat modelBMC Anesthesiology · 2026