Annals of Indian Academy of Neurology

Early GLP-1 Receptor Agonist Therapy in Acute Ischemic Stroke and High-Risk Transient Ischemic Attack: A Systematic Review and Meta-analysis of Randomized Trials.

Aasim Ali, Csilla Dézsi, Viktor Gulyás-Oldal, Piresh Kumar, Károly Szili, Sami Ullah, Nimra Akram, Muhammad Abdullah Gulzar,

Department of Neurology, Faisalabad Medical University, Faisalabad, Pakistan. · Department of Neurology, Szécsényi University - University of Győr, Győr, Hungary.

Meta-analysis

Key points

From the paper's conclusion
  • Early GLP-1RA therapy shows a possible functional benefit, but the finding is fragile and safety evidence remains imprecise. Larger dedicated stroke trials are required before routine clinical use.

Abstract

BACKGROUND AND OBJECTIVES: The role of early glucagon-like peptide-1 receptor agonist (GLP-1RA) therapy after acute ischemic stroke or high-risk transient ischemic attack remains uncertain. We performed a systematic review and meta-analysis of randomized evidence evaluating efficacy and safety in this setting. METHODS: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidance, we included randomized controlled trials evaluating early GLP-1RA therapy in adults with acute ischemic stroke or high-risk transient ischemic attack. Risk ratios (RRs) with 95% confidence intervals (CIs) were pooled using inverse-variance random-effects models with restricted maximum likelihood estimation. The primary outcome was 90-day functional independence (modified Rankin Scale score: 0-2); mortality and symptomatic intracranial hemorrhage (sICH) were critical safety outcomes. RESULTS: Four randomized trials enrolled 1,514 participants: LAMP, GALLOP-1, GALLOP-2, and TEXAIS. GLP-1RA therapy increased 90-day functional independence (547/745 vs 516/752; RR = 1.06; 95% CI: 1.01-1.11; I² = 5.8%), corresponding to an absolute risk difference of 4.8% and number needed to treat of 21. Mortality did not differ significantly (57/749 vs 52/756; RR = 1.13; 95% CI: 0.80-1.61; I² = 0%). sICH was not significantly different (23/579 vs 20/585; RR = 0.67; 95% CI: 0.13-3.42; I² = 67.0%). Excluding LAMP attenuated the functional effect (RR = 1.07; 95% CI: 0.92-1.24), and excluding GALLOP-2 yielded RR = 1.049 (95% CI: 0.999-1.102). CONCLUSIONS: Early GLP-1RA therapy shows a possible functional benefit, but the finding is fragile and safety evidence remains imprecise. Larger dedicated stroke trials are required before routine clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers