Korean circulation journal

Differential Effects of Left Bundle Branch Area Pacing Versus Right Ventricular Pacing on Myocardial Work Indices, Transmural Strain Gradient, and Clinical Outcomes in Patients With Preserved Ejection Fraction.

Özdemir Kuzucu, Nazile Bilgin Doğan, Barış Ünal, Nuri Eren Öget

Department of Cardiology, İzmir Bayraklı City Hospital, Izmir, Turkey. ozdemirkuzucu40@gmail.com. · Department of Cardiology, İzmir Bayraklı City Hospital, Izmir, Turkey.

Observational · n=118

Key points

From the paper's conclusion
  • LBBAP was associated with more synchronous and efficient myocardial mechanics than RVP, and a 70% lower adjusted hazard of the composite endpoint. These hypothesis-generating findings warrant randomised confirmation.

Abstract

BACKGROUND AND OBJECTIVES: Right ventricular pacing (RVP) may impair myocardial mechanics even when ejection fraction (EF) is preserved, whereas left bundle branch area pacing (LBBAP) recruits the His-Purkinje system and may mitigate this. We compared these modalities for myocardial work indices, peak systolic dispersion (PSD) and transmural strain gradient. METHODS: In this retrospective study, 118 patients with preserved EF (≥50%; 58 RVP, 60 LBBAP) underwent speckle-tracking echocardiography before implantation and at 6 months. Pressure-strain loop-derived global work index, global constructive work, global wasted work (GWW), global work efficiency (GWE) and PSD were compared at both visits, and layer-specific global longitudinal strain (GLS) and transmural strain gradient (ΔGLS) at 6 months. The primary mechanistic outcome was the change in PSD (ΔPSD); the primary clinical outcome was a composite of heart failure hospitalisation, new loop diuretic initiation or device-detected atrial fibrillation. Clinical events were monitored for 6 months. RESULTS: At 6 months, RVP showed higher GWW (242.5 vs. 152.5 mmHg·%), lower GWE (88.8% vs. 93.3%), greater PSD (58.5 vs. 40.0 ms) and greater ΔGLS (4.4% vs. 3.2%; all p<0.001). Within-patient changes diverged (ΔPSD +20.5 vs. -17.5 ms; ΔGWE -5.9 vs. -2.5 points; both p<0.001). The composite endpoint occurred in 31.0% vs. 8.3% (hazard ratio [HR], 0.24; 95% confidence interval [CI], 0.09 to 0.65; adjusted HR, 0.30; 95% CI, 0.11 to 0.84). CONCLUSIONS: LBBAP was associated with more synchronous and efficient myocardial mechanics than RVP, and a 70% lower adjusted hazard of the composite endpoint. These hypothesis-generating findings warrant randomised confirmation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers