Screening Bacteriuria Using the Sysmex UF-5000 during Intravesical Bacillus Calmette-Guérin Therapy for Bladder Cancer.
Myung Soo Kim, Do Gyeong Lim, Seung Il Jung, Eu Chang Hwang, Dong Deuk Kwon
Department of Urology, College of Medicine, Ewha Womans University, Seoul, Korea. · Department of Urology, Chonnam National University Medical School, Gwangju, Korea.
Key points
From the paper's conclusion- This study evaluated the ability of the Sysmex UF-5000 urine flow cytometer to detect significant bacteriuria and predict Gram stainability during intravesical BCG.
Abstract
Intravesical Bacillus Calmette-Guérin (BCG) therapy for bladder cancer requires screening for urinary tract infection during treatment, but conventional urinalysis cannot reliably distinguish bacteriuria from BCG-induced inflammatory cystitis. This study evaluated the ability of the Sysmex UF-5000 urine flow cytometer to detect significant bacteriuria and predict Gram stainability during intravesical BCG. This retrospective study included 145 patients who underwent intravesical BCG therapy after transurethral resection of bladder tumors (TURBT). Urine flow cytometry and cultures were performed at baseline, after TURBT, and weekly during BCG instillation. Diagnostic performance was assessed at the patient level over the BCG induction course, using urine cultures (≥105 CFU/mL) as the reference standard. Among 145 patients (median age 71 years; 88.3% male), 37 (25.5%) developed significant bacteriuria. A UF-5000 cutoff of >100 bacteria/µL identified bacteriuria with a sensitivity of 94.6% (95% CI, 82.3-98.5) and specificity of 68.5% (95% CI, 59.3-76.5), and a binary-classifier AUC of 0.816 (95% CI, 0.727-0.905); >1,000 bacteria/µL yielded 62.2% sensitivity, 96.3% specificity, and AUC 0.792. For Gram-stain prediction, sensitivity/specificity reached 83.3%/92.2% (Gram-negative) and 81.0%/84.2% (Gram-positive). The Sysmex UF-5000 shows promise as a rapid screening tool for bacteriuria and Gram-stain prediction during intravesical BCG therapy. Larger prospective studies are needed to validate optimal cutoff values for routine clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safety-focused triage of suspected bacterial urinary tract infection using urine flow cytometry outputs: prediction of culture positivity.Medicinski glasnik : official publication of the Medical Association of Zenica-Doboj Canton, Bosnia and Herzegovina · 2026
- Evaluation of the Sysmex UF-5000 automated urine flow cytometer for detection of urethral inflammation and clinical urethritis in men.Journal of clinical microbiology · 2026
- Bacteriuria screening with the new automated platform AutionMax-AutionEye: when to culture.Clinical chemistry and laboratory medicine · 2026
- Rapid screening of urinary tract infections: quantitative flow cytometry versus dipstick testing in a hospital cohort.Infection · 2026
- Rapid direct-from-urine growth detection to triage culture-negative urine: a prospective diagnostic accuracy study of a two-tube nitrate-reduction and bromothymol blue assay (SIBURI/SIBURI+)medRxiv · 2026
- Culture-Negative Cystitis With Multiorgan Dysfunction and Septic Shock After Intravesical Bacillus Calmette-Guérin (BCG) Therapy: A Case Report and Review of the Literature.Cureus · 2026