Journal of refractive surgery (Thorofare, N.J. : 1995)

Comparison of Visual Outcomes With Different Ablation Profile in FS-LASIK for High Myopia Correction: Ray-Tracing-Guided Versus Custom-Q.

Ruiyu Zhang, Yifei Yuan, Yu Zhang, Ziyuan Liu, Yuexin Wang, Yan Liu, Shuo Yu, Yueguo Chen,

Department of Ophthalmology, Peking University Third Hospital, Beijing, China. · Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania.

Observational · n=66

Key points

From the paper's conclusion
  • Individualized surgeon-adjusted ray-tracing- guided FS-LASIK was safe and effective for correcting high myopia, although a mild tendency toward overcorrection was observed. Compared with Custom-Q ablation, it was associated with lower postoperative SA, particularly at larger optical zones.

Abstract

PURPOSE: To compare visual outcomes in patients with high myopia undergoing individualized ray-tracing-guided femtosecond laser-assisted laser in situ keratomileusis (FSLASIK) versus Q-value-adjusted (Custom-Q) FS-LASIK. METHODS: This prospective contralateral-eye study included 66 eyes of 33 patients with high myopia requiring FS-LASIK. Ray-tracing-guided treatment was performed in one eye and Custom-Q ablation in the fellow eye. For ray-tracing- guided treatment, the ablation profile was generated using a ray-tracing algorithm and subsequently adjusted based on manifest refraction. Follow-up examinations were conducted at 1 day, 1 week, 1 month, and 3 months postoperatively. Visual acuity, manifest refraction, and higher order aberrations (HOAs) were assessed preoperatively and postoperatively. RESULTS: At 3 months postoperatively, uncorrected distance visual acuity (UDVA) of 20/16 or better was achieved in 79% of eyes in the ray-tracing-guided group and 73% in the Custom-Q group. The mean UDVA was -0.10 ± 0.07 logarithm of the minimum angle of resolution (logMAR) in the ray-tracing- guided group and -0.09 ± 0.09 logMAR in the Custom-Q group, with no statistically significant difference between groups (P = .552). Compared with the Custom-Q group, the ray-tracing- guided group showed a tendency toward mild hyperopic shift. Both groups demonstrated significant increases in total HOAs and coma in the 4-mm and 6-mm zones (all P < .05), as well as a significant decrease in SA in the 4-mm zone (P < .001). In the 6-mm zone, no statistically significant increase in SA was observed after surgeon-adjusted ray-tracing-guided FSLASIK (P = .085), and postoperative SA was lower than that in the Custom-Q group (P = .002). CONCLUSIONS: Individualized surgeon-adjusted ray-tracing- guided FS-LASIK was safe and effective for correcting high myopia, although a mild tendency toward overcorrection was observed. Compared with Custom-Q ablation, it was associated with lower postoperative SA, particularly at larger optical zones.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers