Journal of refractive surgery (Thorofare, N.J. : 1995)

Large Language Models for Selecting Intraocular Lens Power Calculation Formulas: A Comparative Study.

Hao Chen, Mingyu Qin, Ruiling Zhu, Xueyan Zhang, Wei Lou

Department of Ophthalmology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Key points

From the paper's conclusion
  • Compared with BUII, current LLMs exhibit limited capacity to improve refractive outcomes by selecting the optimal formulas for routine practice; however, certain LLMs show promise as adjunctive tools for personalized selection tailored to specific ALs.

Abstract

PURPOSE: To evaluate refractive outcomes of large language model (LLM)-based selection of the optimal intraocular lens power calculator according to individual biometric parameters. METHODS: Two hundred eight eyes undergoing routine cataract surgery were included. Ten leading LLMs (Gemini, Chat-GPT, Perplexity, Grok, DeepSeek, Kimi, Qwen, Doubao, ERNIE, and Hunyuan) were prompted to recommend "the single most appropriate formula" from Barrett Universal II (BUII), Cooke K6, EVO 2.0, Hill-RBF 3.0, Kane, and PEARL-DGS, based on axial length (AL), keratometry, anterior chamber depth, and lens thickness. Gemini was excluded because it consistently selected Kane. Precision (SD) and accuracy (absolute spherical equivalent prediction error [SEQ-PE]) were assessed with the Eyetemis Analysis Tool and compared with BUII and SRK/T, both overall and within AL subgroups. RESULTS: Formula preferences varied markedly among LLMs. Overall, all LLMs and BUII demonstrated significantly greater precision than SRK/T, with Hunyuan, ChatGPT, and BUII showing highest precision and significantly improved accuracy compared to SRK/T (all P < .05). The leading percentages of eyes within the ±0.50 diopter (D) threshold were achieved by Perplexity (82.69%), ChatGPT (82.21%), Qwen (82.21%), and BUII (81.73%). Across AL subgroups, at least one LLM numerically outperformed BUII in both precision and accuracy; at the ±0.50 D threshold, certain models increased this percentage over BUII by approximately 3% when AL was ≤ 22 mm or ≥ 26 mm, and by 8% when 24.5 mm ≤ AL < 26 mm. CONCLUSIONS: Compared with BUII, current LLMs exhibit limited capacity to improve refractive outcomes by selecting the optimal formulas for routine practice; however, certain LLMs show promise as adjunctive tools for personalized selection tailored to specific ALs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers