Medial Rectus Inferior Plication in the Management of Near Exodeviations.
Haider Shah, Zakharia Ali, Ian Marsh
Ophthalmology Department, Aintree University Hospital, Liverpool, United Kingdom.
Key points
From the paper's conclusion- MR-iP is a well-tolerated, targeted approach for symptomatic near exodeviations, achieving statistically significant reductions in near angle and disparity while maintaining distance alignment. A practical titration dose of 2 PD/mm is recommended. This procedure expands the surgical options for convergence insufficiency exotropia, with low rates of overcorrection.
Abstract
PURPOSE: To assess outcomes of medial rectus inferior half plication (MR-iP) surgery for the management of near exodeviations, and to define optimal patient selection and surgical dosing for this procedure. METHODS: A retrospective analysis of 39 consecutive MR-iP procedures for near exodeviation, performed by a single surgeon, was conducted. Preoperative and postoperative orthoptic measurements, outcomes, and dose-response relationships were evaluated. RESULTS: Thirty-seven patients underwent 39 MR-iP procedures. The mean age was 47 years (range: 12 to 80 years). Of 39 procedures, 56% were unilateral and 44% were bilateral. Preoperatively, mean distance deviation was 5.7 prism diopters (PD), near deviation was 17.7 PD, and near-distance disparity was 12 PD. Postoperatively, mean distance deviation was 4.5 PD, near deviation was 9.8 PD, and disparity was 5.3 PD, representing a 34% reduction in near angle and 56% reduction in disparity (P < .001). Distance alignment remained unchanged (P = .08). Overall, 70% achieved surgical success, rising to 90.5% when preoperative near deviation was 20 PD or less, but falling to 44.4% when greater than 20 PD. Complications were rare; one patient developed a self-limiting hematoma due to dysplastic cytopenia. No sustained overcorrections occurred. Mean surgical effect was approximately 2 PD/mm plicated. CONCLUSIONS: MR-iP is a well-tolerated, targeted approach for symptomatic near exodeviations, achieving statistically significant reductions in near angle and disparity while maintaining distance alignment. A practical titration dose of 2 PD/mm is recommended. This procedure expands the surgical options for convergence insufficiency exotropia, with low rates of overcorrection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Selective compartmental plication in small-angle convergence insufficiency exotropia: surgical outcomes and predictive model.BMC ophthalmology · 2026
- Early Changes In Accommodative Amplitude After Medial Rectus Resection Versus Plication In Primary Exotropia: A Prospective Comparative Study.Seminars in ophthalmology · 2026
- Comparative Efficacy of Medial Rectus Plication Versus Resection for Exotropia: A Systematic Review and Meta-Analysis.Cureus · 2026
- Reoperations After Lateral Rectus Resection/Plication Versus Medial Rectus Recession for Age-Related Distance Esotropia.American journal of ophthalmology · 2026
- Motor alignment and sensory outcomes in pediatric patients with basic-type intermittent exotropia after bilateral lateral rectus recession versus unilateral recession-resection.BMC ophthalmology · 2026
- Comparison between bilateral lateral rectus recession and bilateral primary medial rectus resection in basic type intermittent exotropia.Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2026