From the paper's conclusion
  • The evaluation showed that the coating may serve to supplement traditional cleaning and disinfection methods. Further research into the efficacy and cost-effectiveness of such antimicrobial coating is needed for overall improvement in patient care.

Abstract

INTRODUCTION: Implementing continuous active disinfection presents challenges as conventional cleaning methods may not fully mitigate risks. Hence, evaluating innovative technologies becomes imperative. This study assessed a nanoparticle-based surface coating containing titanium dioxide engineered into nano-molecules that is activated by normal light and provides ongoing disinfection. METHODOLOGY: The research took place in two intensive care units (ICUs): ICU A (coated) and ICU B (control). Data on healthcare-associated infections (HAIs) and environmental factors were collected pre- and post-coating application to gauge its impact. The change in percentage of positive swabs/HAI cases in ICU A was compared to ICU B and statistically analyzed using a 2-sample test for equality of proportions. RESULTS: ICU A witnessed a 26.5% decrease in positive environment swabs post-coating, while ICU B saw a 160.9% increase. This disparity was statistically significant (p = 0.000). Both ICUs experienced decreased ventilator associated pneumonia (VAP) cases, though central line associated-blood steam infection (CLA-BSI) and catheter associated urinary tract infection (CAUTI) cases increased in ICU A post application. Following coating, positive environmental swabs and VAP decreased by 71.8%, and 72.5%, while CLA-BSI and CAUTI increased by 198% and 43.5%. CONCLUSIONS: The evaluation showed that the coating may serve to supplement traditional cleaning and disinfection methods. Further research into the efficacy and cost-effectiveness of such antimicrobial coating is needed for overall improvement in patient care.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers