Journal of visualized experiments : JoVE

Aesthetic Changes of Edentulous Patients Before and After Full-Arch Implant Restoration by 3D Facial Scanning.

Jiayu Xie, Dan Li, Reinhilde Jacobs, Narisu Hu, Zhihui Tang, Yuwei Wu, Hongyang Ma

Suzhou Stomatological Hospital. · Second Clinical Division, Peking University School and Hospital of Stomatology.

Case report · n=10

Key points

From the paper's conclusion
  • These findings suggest that high-precision 3D facial scanning can quantify facial changes after full-arch implant restoration and that oral implant restorations may improve the convexity of the lower third of the face and lips in edentulous patients, thereby improving facial aesthetics.

Abstract

Edentulism can lead to psychological occlusal fatigue, dysphonia, facial deformity, and reduced quality of life. Recovery of facial aesthetics is a major concern, but traditional two-dimensional photographs cannot accurately evaluate three-dimensional facial changes after full-arch implant restoration. Facial scanning technology enables high-precision facial scanning and measurement. This prospective case series enrolled edentulous patients. Preoperative and postoperative cone beam computed tomography (CBCT) and intraoral scans were obtained and imported into a three-dimensional (3D) facial scanner, where they were reconstructed into 3D models for evaluation. A total of 10 patients (four men and six women) were included. The mean age was 64.9 ± 11.4 years (range, 38-78 years), and the mean follow-up was 15.9 months (range, 12-24 months). All patients underwent 3D facial scanning before and after implant restoration and were evaluated for facial aesthetic parameters. All patients had satisfactory outcomes without major complications. The method accurately validated postoperative facial transformation in all patients. Measured aesthetic parameters indicated favorable improvement in facial contour, including increased lower facial and lip convexity. The nasolabial angle decreased by 5.21° ± 3.8°, vertical distance increased by 4.2 ± 1.3 mm, and perilabial volume increased by 2.2 ± 1.1 cm3. These findings suggest that high-precision 3D facial scanning can quantify facial changes after full-arch implant restoration and that oral implant restorations may improve the convexity of the lower third of the face and lips in edentulous patients, thereby improving facial aesthetics. Further controlled studies are needed to confirm these preliminary observations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers