Journal of visualized experiments : JoVE

Hysteroscopic Fixation of the Levonorgestrel-Releasing Intrauterine System: A Novel Method.

Suer Zhang, Meiqi Li, Qianru Li, Chenyu Xiao, Mengyu Zhang, Leilei Gao, Zhen Jin

Department of Postgraduate Education, Hangzhou Normal University. · Department of Gynecology, Yiwu Tianxiang Medical Oriental Hospital (Yiwu Campus of Dongyang People's Hospital).

Observational · n=140

Key points

From the paper's conclusion
  • Among the 68 patients who completed follow-up, downward displacement occurred in only 1 patient and no complete device expulsion was observed, suggesting that this fixation method may reduce the risk of device expulsion caused by an excessively large uterine cavity or morphological abnormalities, and that it may offer a safe, effective, and highly practicable alternative for patients at high risk

Abstract

The levonorgestrel-releasing intrauterine system (trade name: Mirena) is a drug delivery device that provides localized, sustained, and low-dose release of progestogen within the uterine cavity. It has been widely employed in clinical practice for the management of common gynecological conditions, including menorrhagia, endometrial hyperplasia, and adenomyosis, with generally favorable therapeutic outcomes. However, in patients with adenomyosis or those with a significantly enlarged uterine cavity, the expulsion rate of LNG-IUS under conventional placement methods is as high as 24%-37.5%, which severely compromises both the safety and continuity of treatment and represents a major bottleneck limiting its broader clinical adoption. The LNG-IUS fixation procedure, which anchors the device to the uterine myometrium, can effectively reduce the risk of expulsion, thereby ensuring long-term stable drug release and holding significant potential for clinical promotion. This article aims to introduce a novel hysteroscopic LNG-IUS fixation method that utilizes a self-developed knotted-fixation steel needle surgical system to achieve secure anchoring of the device within the uterine cavity through mechanical fixation. To evaluate the feasibility and clinical efficacy of this technique, we conducted a retrospective analysis of 6-month postoperative follow-up data from 140 patients, of whom 68 underwent fixation, and 72 served as non-fixation controls. The follow‑up focused primarily on assessing device displacement and expulsion, while concurrently evaluating the therapeutic improvement in clinical symptoms. Among the 68 patients who completed follow-up, downward displacement occurred in only 1 patient and no complete device expulsion was observed, suggesting that this fixation method may reduce the risk of device expulsion caused by an excessively large uterine cavity or morphological abnormalities, and that it may offer a safe, effective, and highly practicable alternative for patients at high risk of expulsion, with promising prospects for clinical application.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Hysteroscopic Fixation of the Levonorgestrel-Releasing Intrauterine System: A Novel Method — Science Skim