Transbronchial Cryobiopsy for the Diagnosis of Peripheral Pulmonary Lesions: A Prospective Randomized Controlled Study.
Ying Liang, Hong Zhou, Jie Wu, Xiya Wu
Department of Respiratory and Critical Care Medicine, JiangXi Provincial People's Hospital. · Department of Respiratory and Critical Care Medicine, JiangXi Provincial People's Hospital; 352428819011@ncu.edu.cn.
Key points
From the paper's conclusion- These findings show that R-EBUS-GS-assisted 1.1-mm ultrathin cryobiopsy is technically feasible for PPL sampling and provides larger, better-preserved histologic specimens, while improvement in pathological diagnostic yield was not statistically demonstrated in this small randomized cohort.
Abstract
Peripheral pulmonary lesions (PPLs) are increasingly detected by chest computed tomography, yet bronchoscopic diagnosis remains challenging for small and distal lesions. This prospective, single-center, randomized controlled study evaluated radial endobronchial ultrasound combined with a guide sheath (R-EBUS-GS)-assisted transbronchial cryobiopsy using a 1.1-mm ultrathin cryoprobe. Fifty patients with PPLs were randomized after successful R-EBUS-GS localization to either transbronchial cryobiopsy (TBCB) or conventional transbronchial lung biopsy with forceps (TBLB), with 25 patients in each group. The prespecified primary endpoint was pathological diagnostic yield. Pathological diagnostic yield was 84.0% in the TBCB group and 64.0% in the TBLB group; the difference was not statistically significant (p = 0.107). TBCB yielded a greater maximum total histologic tissue area than TBLB (14.6 ± 4.2 mm2 vs. 3.1 ± 0.9 mm2, p < 0.001) and was associated with a lower frequency of severe crush artifact (8.0% vs. 52.0%, p < 0.001). Grade 2 bleeding occurred in 32.0% and 24.0% of patients, respectively, and no Grade 3 bleeding occurred. One patient in the TBCB group developed pneumothorax and recovered with conservative treatment. These findings show that R-EBUS-GS-assisted 1.1-mm ultrathin cryobiopsy is technically feasible for PPL sampling and provides larger, better-preserved histologic specimens, while improvement in pathological diagnostic yield was not statistically demonstrated in this small randomized cohort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Clinical Impact of Transbronchial Cryobiopsy and Forceps Biopsy Utilizing Radial EBUS Guidance for the Diagnosis of Peripheral Pulmonary Lesions.Tuberculosis and respiratory diseases · 2026
- A modified cryobiopsy specimen retrieval method using a thin bronchoscope and small guide sheath for the diagnosis of peripheral pulmonary lesions.Translational lung cancer research · 2026
- A refined diagnostic approach for interstitial lung disease: efficient and safe transbronchial cryobiopsy using a 1.1-mm cryoprobeFrontiers in Medicine · 2026
- Cryobiopsy vs Forceps for Bronchoscopic Lung Biopsy: The FROSTBITE-2 Randomized Clinical Trial.JAMA · 2026
- Comparison of diagnostic yield between electromagnetic navigation bronchoscopy-guided forceps biopsy and target-fixing technique-assisted RP-EBUS-guided transbronchial cryobiopsy with a guide sheath for peripheral lung lesions.Translational lung cancer research · 2026
- Simultaneous dual cryobiopsy using two bronchoscopes for multiple peripheral lung lesions: a novel case reportThe Egyptian Journal of Bronchology · 2026