From the paper's conclusion- This protocol provides a controlled microfluidic approach for examining how shear flow and channel geometry are associated with the directionality and motility of differentiated HL-60 cells.
Abstract
Neutrophil migration is influenced by mechanical cues within the vascular environment, including shear flow and changes in vessel geometry. This protocol describes the fabrication and use of a custom microfluidic platform designed to investigate cell migration under controlled shear flow across channels of different widths. The device incorporates artery-like, narrow capillary-like, and vein-like regions with channel widths of 1.25, 0.05, and 2.5 mm, respectively. Differentiated HL-60 cells are used as the experimental model, and migration is evaluated under a target shear rate of 800 s-1 on an intercellular adhesion molecule 1 (ICAM-1)-functionalized surface. The protocol details device fabrication, surface functionalization, flow-chamber assembly, cell preparation, migration experiments, and trajectory analysis. Cell trajectories are quantified using migration index, percentage of cells migrating upstream, motility coefficient, persistence time, and migration speed. The platform can also be used to examine changes in migration following blockade of cluster of differentiation 11b (CD11b). Under the conditions presented here, CD11b-blocked differentiated HL-60 cells exhibit upstream migration in the artery-like and vein-like regions, whereas this upstream migratory response is weakened in the narrow capillary-like region. This protocol provides a controlled microfluidic approach for examining how shear flow and channel geometry are associated with the directionality and motility of differentiated HL-60 cells.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Silico Evaluation of Mechanobiological Parameters Under Variable Flow in Three-Dimensional Microfluidic Platforms Supporting Future Cell Migration Studies.Biomedicines · 2026
- Simulation-Based Microfluidic Deformation Mapping for Region-Dependent Apparent Young's Modulus Estimation of Single Cells.Biosensors · 2026
- A microscale approach to investigate how exposure to fluid shear stress enhances the 1D migration of cancer cellsBiomicrofluidics · 2026
- Design-dependent shear and liquid media transport characteristics in microfluidic U-shaped cell traps.Lab on a chip · 2026
- Orthogonal microfluidic approaches reveal force-enhanced migration of bacterial populations on surfaces.bioRxiv : the preprint server for biology · 2026
- Large-Scale Motility Assays for Pooled Functional Screens of Cell Migration.Journal of visualized experiments : JoVE · 2026