Standardized Pelvic Floor Surface Electromyography Assessment in Primiparous Women: Association with Infant Birth Weight.
Yanfang Wu, Ting Wu, Xiaojun He, Juan Lin
Department of Women's Health Care, Fujian Maternity and Child Health Hospital. · Department of Women's Health Care, Fujian Maternity and Child Health Hospital; linjuan2180@fjsfy.com.
Key points
From the paper's conclusion- These findings characterize differences in electrophysiological contraction amplitudes rather than direct measurements of muscle force, and they do not establish a causal effect of birth weight.
Abstract
Infant birth weight may affect pelvic floor loading during pregnancy and childbirth, but the association with early postpartum pelvic floor electrical activity remains uncertain. A standardized five-phase pelvic floor surface electromyography (sEMG) protocol was applied to 14,945 primiparous records assessed 40-70 days after delivery. The dataset included 14,499 records with infant birth weight < 4,000 g and 446 records with birth weight ≥4,000 g. Pre-resting, rapid contraction, tetanic contraction, endurance contraction, and post-resting sEMG amplitudes were compared by birth weight category. Multivariable linear regression estimated adjusted differences in sEMG amplitudes with heteroskedasticity-robust standard errors; models incorporated maternal age, height, body mass index, education, delivery-record category, and gestational weight gain. The ≥4,000 g group had lower mean rapid contraction (32.52 vs. 37.18 µV), tetanic contraction (22.01 vs. 26.19 µV), and endurance contraction (18.78 vs. 21.93 µV) amplitudes. Fully adjusted mean differences (≥4,000 g minus <4,000 g) were -7.21 µV (95% CI -8.79 to -5.64), -5.99 µV (-7.25 to -4.74), and -4.77 µV (-5.85 to -3.70), respectively (all P < 0.001). Exploratory subgroup associations were broadly similar; the forceps-category estimates were imprecise, and interaction tests did not demonstrate clear subgroup heterogeneity. These findings characterize differences in electrophysiological contraction amplitudes rather than direct measurements of muscle force, and they do not establish a causal effect of birth weight.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Twin pregnancy and early postpartum pelvic floor surface electromyographic activity: a single-center retrospective observational study using the glazer sEMG protocol.Frontiers in medicine · 2026
- Experimental Characterization of the Passive Mechanical Behavior of Rat Pelvic Floor Muscles: Effects of Test Conditions and PregnancyarXiv · 2026
- A study on the association between different delivery modes and pelvic floor muscle strength in women during early postpartum period.Frontiers in global women's health · 2026
- Effects of BeBo® Pelvic Floor Muscle Training with and Without Electromyographic Biofeedback After Vaginal Delivery and Cesarean Section: A Randomized Controlled Trial.Journal of clinical medicine · 2026
- Neuromuscular Function Patterns at 6 Weeks Postpartum Characterised Using Latent Profile Analysis: A Cross-Sectional Study of 525 Women.International urogynecology journal · 2026
- Electrical stimulation and biofeedback combined with pelvic floor muscle training for pelvic floor dysfunction in postpartum women: a systematic review and meta-analysis.Frontiers in physiology · 2026