Nomogram for Unqualified Venous Blood Specimens: A Retrospective Case-Control Prediction Study.
Xiaoxiao Guo, Jinkai Luo, Jie Zhang
Department of Nursing, Beijing Friendship Hospital, Capital Medical University. · Department of Nursing, Beijing Friendship Hospital, Capital Medical University; zzhangjie0102@163.com.
Key points
From the paper's conclusion- This retrospective case-control prediction study used inpatient venous blood specimens collected at a tertiary hospital in Beijing between January 1 and December 31, 2024.
Abstract
Unqualified venous blood specimens can delay diagnosis, require repeat venipuncture, and increase pre-analytical workload. This retrospective case-control prediction study used inpatient venous blood specimens collected at a tertiary hospital in Beijing between January 1 and December 31, 2024. The source population comprised 68,451 specimen events, including 473 initially rejected specimens (0.69%). After prespecified exclusions, the analytic cohort included 295 unqualified specimens and 590 month-frequency-sampled qualified controls. The unit of prediction was one specimen-collection event. Twelve clinically prespecified patient, nursing, and process variables were evaluated, and the locked multivariable model contained eight coefficients representing seven retained factors, with age modeled categorically: intravenous infusion during collection, poor vascular condition, transport beyond the hospital-specific allowable time, absence of bedside personal digital assistant verification, collection from 4:00 AM to 8:00 AM, nursing experience of 2 years or less, and age category. The shared training/validation partition comprised 620 and 265 specimen events. The area under the receiver operating characteristic curve (AUC) was 0.844, and the shared validation AUC was 0.827; 1,000-bootstrap optimism correction yielded an AUC of 0.833. A linkage-dependent patient-wise validation sensitivity analysis yielded an AUC of 0.823. Because the case-control sample distorts absolute probabilities, the development-model intercept was recalibrated to the 0.69% source-population rejection prevalence (intercept: -6.724), with 0.43% used in sensitivity analysis (intercept: -7.199). The nomogram is intended for post-collection process monitoring at laboratory receipt before the formal acceptance or rejection decision, not for pre-collection intervention. External validation and prospective implementation testing are required before clinical adoption.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Validation of the Nursing Diagnosis "Risk for Shock" in Patients with Acute Myocardial Infarction Admitted to the ICU.International journal of nursing knowledge · 2026
- B-252 Prospective real-time implementation and clinical validation of patient-based real-time quality control using average of normals in a tertiary hospital laboratorClinical Chemistry · 2026
- Optimizing Laboratory Autoverification in Complete Blood Count Testing Using Machine Learning: A Performance Evaluation Study.Journal of clinical laboratory analysis · 2026
- Construction and validation of a nomogram for venous thromboembolism risk in elderly inpatients: a multicenter retrospective studyBMC Cardiovascular Disorders · 2026
- Association of Initial Peripheral Venous pO2 With 48-Hour Clinical Deterioration in Emergency Department Patients Undergoing Venous Blood Gas Testing.Academic emergency medicine : official journal of the Society for Academic Emergency Medicine · 2026
- Separating biomarker association from incremental EHR value: a reproducible LAR and troponin benchmark in older high-acuity patientsFrontiers in Medicine · 2026