Retrospective Nomogram Development for Postoperative Pulmonary Complications After Robotic-Assisted Anatomical Segmentectomy.
Shuai Shi, Guangrui Wen, Chengqiang Lei, Xiaoqiang Yin, Xiangyong Liu, Xuelin Jiang, Zhi Yang, Jian Liu,
Department of Cardiothoracic Surgery, The People's Hospital of Dazu Chongqing. · Department of Anesthesiology, The People's Hospital of Dazu Chongqing; qingqiang25@hotmail.com.
Key points
From the paper's conclusion- These findings support the potential value of a simple preoperative risk model, but external multicenter validation is required before broader clinical application.
Abstract
Postoperative pulmonary complications (PPCs) remain among the most common adverse events following thoracic surgery, contributing to increased morbidity and prolonged hospital stay. With the growing adoption of robotic-assisted thoracic surgery for anatomical segmentectomy, procedure-specific data on PPC risk stratification remain limited. This retrospective cohort study aimed to evaluate risk factors for PPCs in patients undergoing da Vinci robotic-assisted anatomical segmentectomy and to develop and chronologically validate a nomogram-based prediction model using a homogeneous robotic cohort. The study included 200 patients in the development cohort and 102 patients in the temporal validation cohort. Univariable and multivariable logistic regression analyses were performed in the development cohort, and a three-variable prediction model incorporating age ≥65 years, smoking history, and forced expiratory volume in 1 second (FEV1) <70% predicted was evaluated. Model discrimination was assessed using the area under the receiver operating characteristic curve (AUC), and calibration was assessed using the Hosmer-Lemeshow test and calibration slope. Overall, 64 of 302 patients (21.2%) developed PPCs. In the development cohort, age ≥65 years was independently associated with PPCs (adjusted odds ratio [OR] 2.65, 95% confidence interval [CI] 1.29-5.44, P = 0.008), whereas smoking history (adjusted OR 1.91, 95% CI 0.93-3.91, P = 0.079) and FEV1 <70% predicted (adjusted OR 1.51, 95% CI 0.74-3.10, P = 0.259) were not statistically significant after adjustment. The three-variable model had an AUC of 0.69 (95% CI 0.60-0.78) in the development cohort and 0.85 (95% CI 0.76-0.92) in the temporal validation cohort. These findings support the potential value of a simple preoperative risk model, but external multicenter validation is required before broader clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prediction of postoperative pulmonary complications in geriatric patients with hip fracture using a nomogram incorporating bedside ultrasonography and clinical parametersBMC Geriatrics · 2026
- Development and internal validation of a clinical nomogram for predicting major postoperative pulmonary complications following radical cystectomy: a retrospective cohort study.Translational andrology and urology · 2026
- Perioperative risk scores and predictors for postoperative pulmonary complications in thoracic surgery with one-lung ventilation: A prospective observational study.Asian cardiovascular & thoracic annals · 2026
- Incidence and Risk Factors for Postoperative Delirium Following Robotic and Video-Assisted Pulmonary Lobectomy: Analysis of the Nationwide Inpatient Sample, 2005-2020.Clinical epidemiology · 2026
- Robotic, laparoscopic, and open nephrectomy and 30-day pulmonary morbidity: a procedure-stratified cohort study with intraoperative ventilation data.Journal of robotic surgery · 2026
- Diagnostic Performance and Safety Profile of Shape-sensing Robotic-assisted Bronchoscopy in Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis.Respiration; international review of thoracic diseases · 2026