Smartphone Measurement Application for Percutaneous Vertebroplasty in Osteoporotic Vertebral Compression Fractures: A Randomized Trial.
Jing Wang, Jin Zhang
Department of Orthopaedics, The Second Hospital of Lanzhou University.
Key points
From the paper's conclusion- From October 2025 to March 2026, 43 patients with acute thoracolumbar osteoporotic vertebral compression fractures were allocated using a random-number table to smartphone measurement application (n = 21) or conventional anatomical localization with C-arm verification (n = 22).
Abstract
Accurate vertebral-level localization before percutaneous vertebroplasty (PVP) commonly requires fluoroscopic confirmation, and repeated imaging may prolong the localization workflow. This single-center randomized controlled trial evaluated a smartphone measurement application for transmitting distance data obtained from imaging to the patient's back to assess its clinical efficacy. A smartphone with a rear-facing LiDAR sensor was used as the measurement instrument. The LiDAR's principal function is to acquire high-precision three-dimensional point-cloud data of terrain, object surfaces, and the surrounding environment, thereby enabling accurate determination of object outlines and structures, measurement of distances, and detection of dynamic changes in ground objects. From October 2025 to March 2026, 43 patients with acute thoracolumbar osteoporotic vertebral compression fractures were allocated using a random-number table to smartphone measurement application (n = 21) or conventional anatomical localization with C-arm verification (n = 22). Outcomes included localization time (T0), the number of fluoroscopic images acquired during T0, initial localization accuracy, additional time required to correct a localization deviation (T1), and Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) scores before surgery and at 3 months. Key findings: Compared with conventional localization, the smartphone measurement application resulted in a shorter T0, fewer fluoroscopic images during T0, and a shorter T1 (all P < 0.05). Initial localization accuracy was numerically higher in the smartphone measurement application group, but the between-group difference was not statistically significant (P > 0.05). VAS and ODI scores improved within both groups, with no significant between-group differences at 3 months (P > 0.05). The smartphone measurement application for smartphone measurement application improved localization efficiency without a detectable difference in initial accuracy or short-term clinical outcomes. Because radiation dose was not directly quantified, fewer fluoroscopic images should not be interpreted as proof of a proportional dose reduction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow IntegrationarXiv · 2026
- An Interactive Mobile Augmented Reality System for Efficient Virtual Model-to-Patient Registration in Thoracic SurgeryarXiv · 2026
- Intraoperative three-dimensional imaging-guided vertebral body stenting for cleft-associated very severe osteoporotic vertebral compression fractures: a surgical technique case series.Journal of spine surgery (Hong Kong) · 2026
- Utility of photon-counting CT localizer radiograph in opportunistic bone densitometry.Journal of medical imaging (Bellingham, Wash.) · 2026
- Mobile application-based assessment of rotational changes after surgical treatment for pediatric femoral shaft fracture: A retrospective observational study.Medicine · 2026
- When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopyarXiv · 2026