Risk Factors and Prediction of Medial Canthal Angle Regression after Modified V-Shaped Concealed Flap Canthoplasty.
Jinzhi Zhao, Jin Zhang, Limin Zhu, Xiaorong Li
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital. · Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital; liminzhu2288@outlook.com.
Key points
From the paper's conclusion- These findings support the feasibility of intraoperative quantitative assessment but should be interpreted as internally validated single-center evidence requiring external validation before broader clinical application.
Abstract
This study aimed to define a reproducible intraoperative measurement protocol for modified V-shaped concealed flap canthoplasty and to characterize the association between quantitative folding parameters of the anterior limb of the medial canthal tendon (MCT) and postoperative medial canthal angle regression. In this prospective cohort, 331 consecutive patients undergoing the procedure were enrolled. Intraoperative folding length (L), folding angle (θ), fold-point position (P), fixation plane, and suture tension grade were recorded using a standardized protocol. Medial canthal angle regression at 6 months was assessed from standardized photographs relative to the 1-week postoperative baseline. Multivariable logistic regression was used to explore associations between intraoperative measurements and postoperative regression, and the resulting model was internally validated with bootstrap resampling. The 6-month incidence of medial canthal angle regression was 24.6%. Greater L, θ, and P were protective, whereas tendon/soft-tissue fixation, low suture tension, greater epicanthal fold severity, thick soft tissue, larger preoperative medial canthal angle, and longer operative time were associated with increased risk. The apparent area under the receiver operating characteristic (ROC) curve (AUC) of the internally validated model was 0.85 (95% confidence interval [CI], 0.81-0.89), and the optimism-corrected AUC was 0.81 (95% CI, 0.77-0.85). These findings support the feasibility of intraoperative quantitative assessment but should be interpreted as internally validated single-center evidence requiring external validation before broader clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inversed Bilobed Flap for Medial Canthal Reconstruction.Plastic and reconstructive surgery. Global open · 2026
- Dual-Surface Epicanthoplasty for Conservative-to-Moderate Medial Canthal Opening in East Asian Eyelids.Aesthetic plastic surgery · 2026
- The Course of Nasolabial Angle Loss After Rhinoplasty and Prediction of Late Outcome Using Machine Learning: A Proof-of-Concept Study.Journal of clinical medicine · 2026
- Transcutaneous Levator Aponeurosis Recession Without Spacer Grafts for Upper Eyelid Retraction: A Five-Case Series.Cureus · 2026
- Cosmetic Appearance After Eye Loss: The Role of Prosthesis Motility and Eyelid Function.Journal of clinical medicine · 2026
- A New Method for Creating Lower-Lid Pretarsal Fullness by Fixation of Orbicularis Oculi Muscle-Wrapped Fascia-Fat Flap to the Tarsal Plate.Aesthetic plastic surgery · 2026