Plaque Enhancement Grade on High-Resolution MRI and Recurrent Ischemic Events in Intracranial Stenosis: A Retrospective Cohort Study.
Xiang Zhou, Hong Wei
Quzhou Hospital of Traditional Chinese Medicine. · Quzhou Hospital of Traditional Chinese Medicine; hongwei202602@163.com.
Key points
From the paper's conclusion- This study evaluated the association between high-resolution magnetic resonance imaging (HR-MRI) plaque enhancement grading and recurrent ischemic events and examined its incremental value beyond stenosis rate.
Abstract
Recurrent ischemic events may occur in patients with mild-to-moderate intracranial atherosclerotic stenosis despite standardized medication; stenosis rate alone is insufficient for risk stratification, and plaque activity imaging markers are needed. Because plaque enhancement may reflect plaque activity beyond luminal narrowing, we hypothesized that higher enhancement grade would predict recurrent ischemic events of stenosis rate. This study evaluated the association between high-resolution magnetic resonance imaging (HR-MRI) plaque enhancement grading and recurrent ischemic events and examined its incremental value beyond stenosis rate. In a retrospective medication-treated cohort, patients aged 18-85 years with ischemic stroke or TIA and responsible intracranial arterial stenosis of 30%-69% completed contrast-enhanced HR-MRI within 14 days of onset and received standardized secondary prevention. Enhancement referenced to the pituitary stalk was graded 0-2 with blinded reading. The primary outcome was recurrent ischemic events (stroke or TIA) in the responsible vascular territory. Time-to-event analysis used left truncation. Kaplan-Meier and Cox models adjusted for stenosis rate, LDL-C, age, and imaging interval. Among 381 patients, loss to follow-up was 4.72%. Recurrence occurred in 52 (13.65%) patients; median event time was 171.84 days. Recurrence-free survival differed by enhancement grade (log-rank P = 0.002). Versus grade 0, grade 2 was associated with higher recurrence risk (simplified adjusted HR = 2.50, 95% CI 1.30-4.82; fully adjusted HR = 2.31, 95% CI 1.17-4.56). Per 1-grade increase, risk increased (fully adjusted HR = 1.33, 95% CI 1.07-1.65; trend P = 0.01); grade 1 vs grade 0 was not significant. For stroke recurrence, grade 2 remained associated with higher risk (aHR = 2.63, 95% CI 1.03-6.69). Higher-grade HR-MRI plaque enhancement independently predicts recurrent ischemic events in mild-to-moderate intracranial arterial stenosis and provides incremental risk stratification beyond stenosis rate, supporting the study hypothesis and identifying patients requiring intensified follow-up and risk-factor target achievement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association of Myeloperoxidase and Granulocyte Colony-Stimulating Factor With Intracranial Atherosclerosis Presence and Progression From a Community-Based Study.Journal of the American Heart Association · 2026
- Natural history of MRI-defined intraplaque hemorrhage-positive asymptomatic carotid stenosis in the contemporary medical era: a prospective multicenter cohort study.Neurosurgical review · 2026
- Application of high-resolution magnetic resonance imaging for stroke involving the middle cerebral artery with non-significant stenosisBMC Neurology · 2026
- A higher triglyceride-glucose index is independently associated with recent intraplaque hemorrhage in patients with severe carotid stenosisFrontiers in Cardiovascular Medicine · 2026
- Preprocedural high-resolution vessel wall MRI predicts in-stent restenosis after intracranial stenting.Journal of neurointerventional surgery · 2026
- Beyond plaque morphology: a multimodal imaging model combining structural vulnerability and functional reserve predicts stroke recurrence in symptomatic intracranial atherosclerosis.Quantitative imaging in medicine and surgery · 2026