Can electrical impedance tomography predict successful mechanical ventilation weaning in tracheostomized patients? A single-center observational study.
Walkyria A Macedo Pinto, Flávio G R Freitas, Fernando J S Ramos, Renato H N Santos, Flávia R Machado
. Unidade de Terapia Intensiva, Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo (SP) Brasil. · . Programa de Pós-Graduação em Medicina Translacional, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo (SP) Brasil.
Key points
From the paper's conclusion- The EIT variables evaluated in our study did not behave differently between tracheostomized patients who were successfully weaned from IMV and those who were not. The addition of EIT variables did not improve the accuracy of failure prediction models.
Abstract
OBJECTIVE: To evaluate whether ventilation variables monitored by electrical impedance tomography (EIT) behaved differently between tracheostomized patients who progressed successfully or failed within 6 h after withdrawal of invasive mechanical ventilation (IMV), as well as to improve the accuracy of failure prediction models. METHODS: This was a single-center prospective observational study including tracheostomized adults who had been on IMV for more than seven days and who were clinically ready for discontinuation. Clinical and EIT variables-end-expiratory lung impedance, impedance variation, center of ventilation, heterogeneity index, and ventilation distribution-were collected. The primary outcome measure was IMV weaning failure within 6 h, defined as the need to resume IMV for respiratory distress. Associations between EIT variables and failure were tested by using multivariate logistic regression and ROC curves to assess predictive accuracy. RESULTS: Fifty-nine patients were analyzed; 43 (72.9%) were successfully weaned from IMV, and 16 (27.1%) failed. In the region of interest H1 (ventral lung region), end-expiratory lung impedance decreased more markedly among successfully weaned patients (p = 0.03). Respiratory rate behavior differed between the groups over time (interaction p = 0.01), whereas other EIT variables showed no group-time interaction. In the multivariate analysis, BMI and 24-hour fluid balance were independently associated with failure. Adding EIT variables to clinical models did not improve predictive accuracy. CONCLUSIONS: The EIT variables evaluated in our study did not behave differently between tracheostomized patients who were successfully weaned from IMV and those who were not. The addition of EIT variables did not improve the accuracy of failure prediction models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrical impedance tomography for predicting weaning failure from mechanical ventilation: a systematic review and meta-analysisFrontiers in Medicine · 2026
- Dynamic changes in regional ventilation distribution and end-expiratory lung impedance using electrical impedance tomography: associations with weaning and extubation outcomes.Frontiers in medicine · 2026
- Negative inspiratory force predicts extubation failure after planned extubation in a medical ICU: a prospective cohort study.Intensive & critical care nursing · 2026
- Diaphragm ultrasound parameters and rapid shallow breathing index for predicting weaning failure in mechanically ventilated infants: a prospective observational PICU study.European journal of pediatrics · 2026
- Integrated comprehensive assessment for predicting weaning success in difficult-to-wean critically ill patients: the WEAN-US studyCritical Care · 2026
- Electrical Impedance Tomography Accurately Reflects Regional Ventilation Distribution Compared With Computed Tomography in Non-Intubated SubjectsRespiratory Care · 2026