Designing and fabrication of 4H-SiC neutron sensors for boron neutron capture therapy
Vu Thi Ha, Tatsuya Meguro, Kazutoshi Kojima, Hiroki Tanaka, Shin-Ichiro Kuroki
Key points
From the paper's conclusion- The results, which were obtained under the HWNIF condition with a high neutron flux in the range of 1 x 109 n/cm2.s and a cycle of 1.0 s, demonstrated the neutron detection capability of the 4H-SiC neutron sensor prototypes, despite signs of degradation due to neutron-induced damage and the TID effects.
Abstract
In this work, 4H-SiC neutron sensors for BNCT were designed, fabricated and tested under UV light and neutron irradiation. A pinned photodiode (PPD) structure and a parasitic bipolar junction transistor were designed for neutron sensor region. A large neutron conversion layer of 500 µm x 500 µm was formed on the PPD area by 10B ions implantation into a 700-nm Al layer. The output characteristics under UV light test have demonstrated the functional operation of the 4T-APS structure of SiC neutron sensors. No significant degradation was observed under E-3 tube with total neutron fluence of 1.8 x 109 n/cm2. The results, which were obtained under the HWNIF condition with a high neutron flux in the range of 1 x 109 n/cm2.s and a cycle of 1.0 s, demonstrated the neutron detection capability of the 4H-SiC neutron sensor prototypes, despite signs of degradation due to neutron-induced damage and the TID effects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Voltage 4H-SiC PiN Diodes: Ion Implantation vs. Epitaxial Growth for Wide-Temperature OperationMaterials · 2026
- Analysis of Electrical Performance Degradation of 4H-SiC Junction Barrier Schottky Diodes Induced by Neutron IrradiationIEEE Transactions on Device and Materials Reliability · 2026
- Decoupling sublattice dynamics in low-dose neutron-irradiated 4H-SiC via two-component density functional theory guided positron annihilation spectroscopyJournal of Applied Physics · 2026
- 4H-SiC Diodes to Probe Stark Effect Detection in 7Be Decay LifetimeMaterials science forum · 2026
- Neutron irradiation damage on Silicon Photomultipliers and in-situ current annealing studies for the CBM RICH detectorNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- Neutron Conversion Layers for Semiconductor Neutron Detectors: A Review of Materials, Thin-Film Deposition Technologies, and Performance Optimization.Sensors (Basel, Switzerland) · 2026