Japanese Journal of Applied Physics

Hydrogen gas response of quartz crystal microbalance sensors coated with nitrogen-containing and nitrogen-free amorphous carbon films

Shun Kitazawa, Kazuya Kanasugi, Yasushi Ishiguro, Ali Alanazi, Kenji Hirakuri

Key points

From the paper's conclusion
  • We focused on the quartz crystal microbalance (QCM) method, capable of low-temperature operation, and proposed a novel H2 sensor utilizing amorphous carbon (a-C) and nitrogen-containing amorphous carbon (a-C:N) films as the detection layer.

Abstract

A safety-conscious hydrogen society requires new hydrogen gas (H2) sensors with simple structures, using no precious metals, and capable of room-temperature operation. We focused on the quartz crystal microbalance (QCM) method, capable of low-temperature operation, and proposed a novel H2 sensor utilizing amorphous carbon (a-C) and nitrogen-containing amorphous carbon (a-C:N) films as the detection layer. Four types of a-C:N films with different thicknesses ranging from 25 to 270 nm and one type of a-C film were deposited onto QCM elements. The test results showed that the uncoated QCM element exhibited no H2 response, whereas the QCM elements coated with a-C or a-C:N films demonstrated a noticeable H2 response. Furthermore, the H2 response increased approximately linearly with increasing a-C:N film thickness. Surface roughness also increased with increasing film thickness. These results demonstrate the potential application of such thin films in QCM-type sensors.

Read the paper