A Bionic Multichannel Whisker System for Assisting Endoluminal Intervention.
Zeyu Wang, Frank P-W Lo, Junhong Chen, Jianing Qiu, Qian Chen, Yongqi Zhang, Chen Lin, Kyle Lam,
Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London SW7 2AZ, UK. · Department of Personalized Medicine, Mohamed bin Zayed University of Artificial Intelligence, Building 1B, Masdar City, P.O. Box 7909, Abu Dhabi, United Arab Emirates.
Key points
From the paper's conclusion- Inspired by the tactile sensing mechanisms of rat whiskers, this study introduces a bionic multichannel whisker system, as an additional sensing modality for endoluminal interventions.
Abstract
Endoluminal interventions are crucial for both the diagnosis and treatment of gastrointestinal diseases. However, conventional endoscopic systems are designed for visual inspection and diagnosis, limiting their capacity to assess critical tissue properties such as texture, stiffness, and structural integrity. These unobserved mechanical signatures may contribute to clinically relevant failure modes, including missed lesions, incomplete resection, and adverse events driven by excessive wall loading. Inspired by the tactile sensing mechanisms of rat whiskers, this study introduces a bionic multichannel whisker system, as an additional sensing modality for endoluminal interventions. The system integrates high-fidelity tactile sensing hardware, and advanced signal processing algorithms, enabling precise and reliable measurements of tissue properties, as well as providing real-time radial force feedback. Calibration via affine transformation ensures cross-channel consistency and compensates for manufacturing and installation variances. Validation across multiple experimental settings, including robotic and manual operation, demonstrates performance in texture discrimination, shape reconstruction, and radial force estimation. The presented whisker system is compact to support integration with endoscopic instruments, providing a practical basis for complementing endoluminal diagnostic workflows and for further development of tactile sensing in surgical robotics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnetic catheter robot with dynamic force feedback for stiffness identification and abnormality detection.Fundamental research · 2026
- EndoTac: An Endoscopic Camera‐Based Tactile Sensor with High Sensitivity for Minimally Invasive SurgeryAdvanced Science · 2026
- Haptic and Palpation Sensing for Robotic Surgery: Engineering Perspectives on Design and IntegrationSensors · 2026
- MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping FeedbackarXiv · 2026
- Exploring RGBD Models for Force Estimation in Surgical Manipulation of Small IntestineCurrent Directions in Biomedical Engineering · 2026
- Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive SurgeryarXiv · 2026