BME frontiers

Physics-Based Flow-Mediated Dilation Reveals Altered Mechanotransduction in Type 1 Diabetes.

Bingjie Zhou, Sridhar Santhanam, Bchara Sidnawi, Lincoln Marshall, Abigayle B Simon, Matthew S Nicholson, Ryan A Harris, Qianhong Wu

Department of Mechanical Engineering, College of Engineering, Villanova University, Villanova, PA 19085, USA. · Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA 19122, USA.

Key points

From the paper's conclusion
  • Objective: To evaluate the first clinical application of the Wu-Sidnawi biophysical framework to flow-mediated dilation (FMD) test and investigate whether it could provide complementary mechanistic characterization of vascular alterations associated with type 1 diabetes (T1D).

Abstract

Objective: To evaluate the first clinical application of the Wu-Sidnawi biophysical framework to flow-mediated dilation (FMD) test and investigate whether it could provide complementary mechanistic characterization of vascular alterations associated with type 1 diabetes (T1D). Impact Statement: This study demonstrates the clinical utility of the Wu-Sidnawi framework by providing complementary mechanistic insight into vascular function and suggesting altered model-derived vascular mechanotransduction from routine FMD measurements. Introduction: FMD test is a widely used noninvasive assessment of endothelial function, but conventional metrics do not explicitly characterize the mechanobiological processes governing the vascular response. The Wu-Sidnawi framework dynamically models the complete FMD response and estimates 5 physiologically meaningful parameters representing distinct aspects of vascular biomechanics. Methods: Previously acquired FMD recordings from 69 individuals with T1D and 38 healthy controls were reanalyzed. Continuous brachial artery diameter-time profiles were used to estimate model-derived parameters. Conventional and model-derived metrics were compared between groups, and correlation, covariate-adjusted regression, and logistic regression analyses with internal cross validation were performed to evaluate their relationships and ability to characterize vascular alterations. Results: Conventional FMD metrics, including percentage FMD, showed no statistically significant group differences. In contrast, the vaso-mechanotransduction index was nominally lower in participants with T1D ( 1.39 ± 0.90 vs . 1.76 ± 1.16 × 10 - 3 , P = 0.045 ), indicating altered model-derived vaso-mechanotransduction. Wu-Sidnawi parameters provided information complementary to conventional metrics, and combining both parameter sets increased McFadden's pseudo-R 2 from 0.008 to approximately 0.11. Conclusion: The Wu-Sidnawi framework extends conventional FMD analysis by providing complementary model-derived biophysical descriptors that improve characterization of vascular dysfunction in T1D.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers