Effect of Drug-Coated Balloons on Recurrent Venous Hypertension Due to Central Venous Lesions in Patients with Hemodialysis Vascular Access.
Daihiko Eguchi, Kenichi Honma
Department of Vascular Surgery, Fukuoka City Hospital, Fukuoka, Fukuoka, Japan.
Key points
From the paper's conclusion- DCBs demonstrated satisfactory efficacy for recurrent central venous lesions, which was maintained with repeated use. Additionally, pre-dilatation using PCBs showed a trend toward improved patency rates. (This is a translation of Jpn J Vasc Surg 2026; 35: 23-28.).
Abstract
OBJECTIVES: This study aimed to evaluate the efficacy of drug-coated balloons (DCBs) for symptomatic and recurrent central venous lesions (including in-stent restenosis and occlusion) in patients undergoing hemodialysis. METHODS: Twenty-seven patients treated with DCBs for symptomatic central venous lesions between June 2021 and September 2025 were included. We examined the overall efficacy of DCBs, the outcomes of repeated use, and factors affecting patency. RESULTS: Target lesion patency at 6 months was significantly improved following initial DCB use (77% vs. 30% prior to DCB use, p <0.0001). The efficacy of repeated DCB use was not significantly different between the first and second applications. In a subgroup analysis, there was a trend toward better patency rates in patients treated with peripheral cutting balloons (PCBs) for pre-dilatation compared to those treated with conventional balloons, although the difference was not statistically significant. CONCLUSIONS: DCBs demonstrated satisfactory efficacy for recurrent central venous lesions, which was maintained with repeated use. Additionally, pre-dilatation using PCBs showed a trend toward improved patency rates. (This is a translation of Jpn J Vasc Surg 2026; 35: 23-28.).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Recurrent Arteriovenous Fistula Stenosis: Identifying Patients Most Likely to Benefit From Drug-Coated Balloon Therapy.The American surgeon · 2026
- Two-year patency rates of drug-coated balloon angioplasty for radiocephalic arteriovenous fistula juxta-anastomotic stenosis: A single-center study.The journal of vascular access · 2026
- Drug-coated balloon angioplasty in coronary artery disease: state of the art reviewnpj Cardiovascular Health · 2026
- The application of drug-coated balloon to in situ short and long lesions of large coronary artery vessels.Frontiers in cardiovascular medicine · 2026
- Inflammation-associated clinical prognostic factors and primary patency after drug-coated balloon angioplasty for recurrent autogenous arteriovenous fistula stenosis: a single-center retrospective cohort study.Frontiers in cell and developmental biology · 2026
- Drug-coated balloon for the side branch compared with conventional strategy in left anterior descending-diagonal bifurcation lesions.REC, interventional cardiology · 2026