Water

Design and Field Validation of a Low-Cost IoT-Enabled Smart Boat for Real-Time Urban Water Quality Monitoring

Mirza Md Tasnim Mukarram, Abdulla Al Kafy, Md. Iquebal Hossain, Hamad Ahmed Altuwaijri

Key points

From the paper's conclusion
  • We report the design, construction, and field validation of a low-cost Internet of Things (IoT)-enabled unmanned surface vehicle, the smart boat, which carries pH, water temperature, turbidity, and nitrate sensors with an IP camera and Bluetooth and GSM/GPRS telemetry for USD 600 in hardware.

Abstract

Urban water managers in resource-limited settings need spatially distributed, near-real-time water quality data, yet affordable mobile platforms validated against reference measurements at the density that management use requires remain scarce. We report the design, construction, and field validation of a low-cost Internet of Things (IoT)-enabled unmanned surface vehicle, the smart boat, which carries pH, water temperature, turbidity, and nitrate sensors with an IP camera and Bluetooth and GSM/GPRS telemetry for USD 600 in hardware. We validated it at 61 stations in BUP Lake, Dhaka, Bangladesh, with eight reference samples per 140 min occupation (488 pairs per parameter) and repeated-measures agreement methods. Root mean square error was 0.148 pH, 0.265 °C, 2.208 NTU, and 0.660 mg/L. With stations as the resampling unit, slope intervals included unity for all four parameters, and the Deming interval excluded unity only for turbidity. A mixed-effects decomposition attributed 95 to 99% of the variance in the device-reference difference to between-station offsets. A global linear correction evaluated on withheld stations removed mean bias but left RMSE unchanged, whereas a one-point offset from the first reference pair at a station, applied to the remaining pairs of the same occupation, reduced RMSE by 70 to 89%. The five-year cost of ownership is USD 1968. Under an equivalent workload, screening with 10% confirmatory laboratory samples costs 86% less than a conventional laboratory program, and station-referenced monitoring costs 75% less with a portable field kit and 8% less with laboratory samples at every visit. Within the validated envelope of one warm urban lake, the platform serves screening and spatial reconnaissance with a reference pair at each station visit; it is not a tool for regulatory reporting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers