Cumulative Thermal Effect Assessment and Zoning Compatibility Analysis of Multi-Source Thermal Discharges in a Semi-Enclosed Bay
Ruer Sun, Zhun Xu, Shiqiang Wu
Key points
From the paper's conclusion- Results show the following: (1) Intake recirculation significantly reduces the effective thermal load discharged into the bay, and the 1 °C temperature-rise envelope is reduced by 49.2% after intake flow correction. (2) Under the benchmark parameter, the bay-scale thermal environmental capacity utilization rate is 90.7% with approximately 2000 MW residual capacity, and the comprehensive uncertaint
Abstract
Semi-enclosed bays subject to intensive thermal discharges present significant challenges in quantifying cumulative thermal effects and assessing thermal environmental carrying capacity. Taking Daya Bay as the study site, this paper develops a two-dimensional hydrodynamic–thermal coupling model using MIKE 21 FM to simulate the spatially integrated temperature rise field induced by four thermal discharge sources under a worst-case hydro-meteorological scenario—characterized by neap tide conditions and a low wind speed of 1.5 m/s. Model performance is rigorously validated against in situ monitoring data and Landsat-derived sea surface temperature observations. Building upon this validated simulation framework, the thermal environmental carrying capacity is quantified via the contour-constraint method, and the spatial compatibility between the simulated temperature-rise contours and designated marine functional zones is systematically evaluated. Results show the following: (1) Intake recirculation significantly reduces the effective thermal load discharged into the bay, and the 1 °C temperature-rise envelope is reduced by 49.2% after intake flow correction. (2) Under the benchmark parameter, the bay-scale thermal environmental capacity utilization rate is 90.7% with approximately 2000 MW residual capacity, and the comprehensive uncertainty range is ±13% to ±17% considering parameter sensitivity. (3) The 1 °C temperature-rise contour overlaps with the core protected area by about 8.7 km2, showing potential spatial conflict with ecological zoning. This study offers technical support for optimizing the spatial layout of thermal discharges and implementing total load control in semi-enclosed bays.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of discharge flow and reservoir water level on intake water temperature with a front retaining wallAIP Advances · 2026
- Regional-Scale Development Assessment of Heterogeneous Geothermal Reservoirs: Digital Reconstruction of Parameter Maps, Spatially Constrained Zoning, and Coupled Groundwater Flow and Heat Transport SimulationEnergies · 2026
- Hydraulic–thermal dynamic model of meshed district heating network based on discrete event simulationEnergy · 2025
- Model Selection for Biological Blockage at Cooling Water Intakes: A Structured Critical Review of CFD, FSI, CFD–DEM, and Surrogate ModelsApplied Sciences · 2026
- Hydrodynamic Modeling of Flow Velocity and Sedimentation in the Tuyamuyun Channel Reservoir on the Amu Darya RiverLimnological Review · 2026
- Multiscale Modeling Methods for District Heating Systems: From Physics-Based Approaches to Data-Driven IntegrationEnergies · 2026