Water

Experimental Evaluation of a One-Dimensional Capacity Model for a Locally Fabricated Coanda-Effect Screen

Eduardo Carrión-Coronel, Richar J. Rivas Loaiza, Juan D. Carrión Coronel

Key points

From the paper's conclusion
  • A locally fabricated flat screen (0.8 mm slot, 7.6 mm wire, 4.75° tilt) was tested behind four Ogee accelerator plates, combining drop heights of 0.10 m and 0.15 m with tangency angles of 45° and 50°, over 52 clear-water runs at 2.2 to 21.4 L/s.

Abstract

Coanda-effect screen capacity is commonly predicted with a one-dimensional model whose slot discharge coefficient depends on the angle of attack of the flow. That angle combines a geometric component, fixed by the wire, and a flow component that varies with the Froude number. Wires machined from square steel bar are wide relative to the slot, which displaces that component. A locally fabricated flat screen (0.8 mm slot, 7.6 mm wire, 4.75° tilt) was tested behind four Ogee accelerator plates, combining drop heights of 0.10 m and 0.15 m with tangency angles of 45° and 50°, over 52 clear-water runs at 2.2 to 21.4 L/s. The geometric component alone is 36.2°, so the total angle of attack exceeded the 16° to 34° range of the data supporting the default coefficients in every run. Over the 34 informative runs the model overpredicted capture, with mean absolute relative deviations of 5.63% at 45° and 1.58% at 50°, reaching 12.6%. The deviation grew 0.91 percentage points per L/s faster at 45° (95% CI 0.64 to 1.18), significant in three of four analysis combinations. The geometric component should be computed from the workshop drawing before the default coefficients are used, and capacities verified by test.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers