Establishment of Recombinase-Aided Amplification Combined with Lateral Flow Dipstick for Rapid Detection of Yersinia pestis Based on the pla Gene.
Yunhan Zhou, Xue Yang, Ziling Ding, Qiuyu Fan, Xiaofang Yan, Haifeng Liu, Ziyao Zhou, Zhijun Zhong,
Key Laboratory of Animal Disease and Human Health of Sichuan, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.
Key points
From the paper's conclusion- This study establishes a rapid detection method for Yersinia pestis that combines recombinase-aided amplification with a lateral flow dipstick (RAA-LFD) and targets the pla gene.
Abstract
This study establishes a rapid detection method for Yersinia pestis that combines recombinase-aided amplification with a lateral flow dipstick (RAA-LFD) and targets the pla gene. Based on the pla gene sequences of six representative strains from NCBI, three primer pairs (P-F1/R1, P-F2/R2, and P-F3/R3) and one RAA-nfo probe were designed. The RAA-LFD assay was constructed and evaluated for sensitivity, specificity, repeatability, and clinical applicability. Initial screening via polymerase chain reaction followed by agarose gel electrophoresis (PCR-AGE) showed P-F3/R3 produced a faint band, while P-F1/R1 and P-F2/R2 yielded bright, specific bands. RAA-LFD condition optimization demonstrated that: clear test lines (T lines) were observable at primer concentrations of 250-2000 nM, with the strongest signal at 2000 nM; the T line signal of P-F1/R1 remained stable at 35-41 °C, peaking slightly at 39 °C, whereas P-F2/R2 decreased markedly at 35 °C (p < 0.01); and the integrated optical density (IOD) of the T line increased with reaction time from 5 to 30 min, with a significant difference between 5 and 30 min (p < 0.001). The optimal reaction conditions were consequently determined as follows: primer pair P-F1/R1, a final primer concentration of 2000 nM, and incubation at 39 °C for 30 min. All five Y. pestis strains tested positive, while seven non-target strains and blank controls were negative, consistent with PCR results. Regarding sensitivity, the limit of detection (LOD) of RAA-LFD was 3.8 × 102 copies/μL, approximately 10-fold lower than conventional PCR (3.8 × 103 copies/μL). In the repeatability evaluation, intra-assay CVs were 1.79%, 0.59%, and 7.76%; inter-assay CVs were 1.75%, 2.35%, and 1.70%, all within 10%. Results for 130 clinical samples showed 100% agreement with PCR and qPCR. RAA-LFD established in this study provides a reliable, simple approach for on-site plague screening and primary laboratory diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid visual detection of Streptococcus agalactiae in tilapia using recombinase polymerase amplification combined with lateral flow strips.Antonie van Leeuwenhoek · 2026
- Four Recombinase-Aided Amplification Assays for the Rapid Detection of Fowl Adenovirus Serotype 4.International journal of molecular sciences · 2026
- A Comprehensive Visual Detection Strategy: Versatile LAMP Assay with Phenol Red and Lateral Flow Dipstick for On-Site Detection of Riemerella anatipestiferMicroorganisms · 2026
- Establishment of RPA-CRISPR/Cas12a Detection Methods for Rapid Largemouth Bass Ranavirus Surveillance.Veterinary sciences · 2026
- Development of a visual RAA-LFA Sensor platform for detection of Vibrio cholerae via the OmpW gene.Enzyme and microbial technology · 2026
- Rapid and visual differentiation of pseudorabies virus vaccine and wild-type strains using an RPA-LFD assay.BMC veterinary research · 2026