Utility of the Heart-to-Single Vertebra Ratio Compared with Artificial Intelligence-Derived Vertebral Heart Score for Detecting Cardiomegaly in Dogs with Myxomatous Mitral Valve Degeneration.
Berfin Eftelya Güder, Zeynep Nurselin Kot, Viktor Szatmári
Department of Internal Medicine, Faculty of Veterinary Medicine, Ondokuz Mayıs University, 55280 Samsun, Türkiye. · Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 108, 3584 CM Utrecht, The Netherlands.
Key points
From the paper's conclusion- Overall, HSVR-T7 was less sensitive and specific in detecting cardiomegaly in dogs with myxomatous mitral valve disease than VHS, and it cannot replace echocardiographic, VHS or VLAS measurements.
Abstract
The heart-to-single vertebra ratio measured at the seventh thoracic vertebra (HSVR-T7) is a recently described radiographic method used to assess heart size in dogs. Our study evaluated the diagnostic performance of HSVR-T7 for identifying echocardiographically defined cardiomegaly in dogs with myxomatous mitral valve disease (MMVD). Its correlation with vertebral heart score (VHS) and vertebral left atrial size (VLAS), and as its discriminatory performance compared with artificial intelligence (AI)-derived VHS and VLAS measurements were investigated. Radiographs of 93 dogs with echocardiographically confirmed myxomatous mitral valve disease were included; 35 were classified as ACVIM stage B1 and 58 as stage B2 or C. Among the 35 stage B1 dogs, five (14.3%) had isolated left atrial enlargement and two (5.7%) had isolated left ventricular enlargement. The HSVR-T7 scores were significantly higher in dogs with echocardiographically confirmed cardiomegaly (stage B2 or C) than in dogs without cardiomegaly (stage B1): 11.65 ± 1.13 versus 10.47 ± 1.08 (p < 0.001). At the optimal cut-off value of ≥11.15, HSVR-T7 yielded an area under the curve (AUC) of 0.769 of the receiver operating characteristic (ROC) curve, with 70.7% sensitivity and 74.3% specificity. The HSVR-T7 showed a very strong positive correlation with VHS (r = 0.890; p < 0.001). Artificial intelligence-derived VHS showed the highest diagnostic performance at an optimal cut-off value of ≥11.35 (AUC, 0.861; sensitivity, 75.9%; specificity, 82.9%), whereas AI-derived VLAS yielded an AUC of 0.765, with 62.1% sensitivity and 85.7% specificity at an optimal cut-off value of ≥2.65. Overall, HSVR-T7 was less sensitive and specific in detecting cardiomegaly in dogs with myxomatous mitral valve disease than VHS, and it cannot replace echocardiographic, VHS or VLAS measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Anatomical Representation to Quantitative Measurement: A Deep Learning-Based Multi-View Framework for Automated Cardiac Size Assessment in Canine Thoracic RadiographsAnimals · 2026
- Predicting stage B2 myxomatous mitral valve disease in dogs using machine learning and routine clinical data.Frontiers in veterinary science · 2026
- Evaluation of the mitral-aortic velocity time integral ratio for severity assessment in dogs with myxomatous mitral valve disease.Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2026
- Geometric morphometric analysis of cardiac shape changes associated with myxomatous mitral valve disease in Cavalier King Charles Spaniels.Veterinary journal (London, England : 1997) · 2026
- Prognostic interaction between clinical stage and left atrial remodeling in dogs with myxomatous mitral valve diseaseVeterinary Quarterly · 2026
- Radiographic Comparison of Pulmonary Lobar Vasculature Dimensions in Medically Managed and Drug‐Naive Dogs With Left Heart Failure Secondary to Myxomatous Mitral Valve DiseaseVeterinary Radiology & Ultrasound · 2026